Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
A mini-fluid challenge of 150mL predicts fluid responsiveness using ModelflowR pulse contour cardiac output directly
Annemieke Smorenberg1, Thomas G V Cherpanath2, Bart F Geerts1
1Department of Anesthesiology, Amsterdam Medical Center, 1109 AZ Amsterdam, The Netherlands.
Study Objective:
The mini-fluid challenge may predict fluid responsiveness with minimum risk of fluid overloading. However, the amount of fluid as well as the best manner to evaluate the effect is unclear. In this prospective observational pilot study, the value of changes in pulse contour cardiac output (CO) measurements during mini-fluid challenges is investigated.
Design:
Prospective observational study.
Setting:
Intensive Care Unit of a university hospital.
Patients:
Twenty-one patients directly after elective cardiac surgery on mechanical ventilation.
Interventions:
The patients were subsequently given 10 intravenous boluses of 50mL of hydroxyethyl starch with a total of 500mL per patient while measuring pulse contour CO.
Measurements:
We measured CO by minimal invasive ModelflowR (COm) and PulseCOR (COli), before and one minute after each fluid bolus. We analyzed the smallest volume that was predictive of fluid responsiveness. A positive fluid response was defined as an increase in CO of >10% after 500mL fluid infusion.
Main Results:
Fifteen patients (71%) were COm responders and 13 patients (62%) COli responders. An increase in COm after 150mL of fluid >5.0% yielded a positive and negative predictive value (+PV and -PV) of 100% with an area under the curve (AUC) of 1.00 (P<0.001). An increase in COli >6.3% after 200mL was able to predict a fluid response in COli after 500mL with a +PV of 100% and -PV of 73%, with an AUC of 0.88 (P<0.001).
Conclusion:
The use of minimal invasive ModelflowR pulse contour CO measurements following a mini-fluid challenge of 150mL can predict fluid responsiveness and may help to improve fluid management.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
The Fluid Mosaic Model