Related Experiment Video
Updated: Feb 15, 2026

Closed System Cell Culture Protocol Using HYPERStack Vessels with Gas Permeable Material Technology
Published on: November 29, 2010
Silicone Hydrogel and Rigid Gas-Permeable Scleral Lens Tear Exchange.
Jerry R Paugh1, Elaine Chen, Colton Heinrich
1Southern California College of Optometry (J.R.P., E.C., T.E., B.A.W.), Marshall B. Ketchum University, Fullerton, CA; Private Practice (C.H.), College Station, TX; Department of Ophthalmology (H.M.), University of California, Davis, Sacramento, CA; Private Practice (T.G.), Broomfield, CO; Department of Mathematics, California State University (A.L.N.), Fullerton, CA; and Stein Eye Institute (B.A.W.), David Geffen School of Medicine at UCLA, Los Angeles, CA.
Scleral gas permeable (GP) contact lenses (CLs) showed significantly lower tear elimination rates (ER) compared to silicone hydrogel (Si-Hy) CLs. This indicates better tear exchange under scleral GP CLs for improved ocular comfort and health.
Area of Science:
- Ophthalmology
- Biomaterials Science
- Corneal Physiology
Background:
- Contact lens wear can alter the natural tear film dynamics.
- Understanding tear elimination rate (ER) is crucial for assessing contact lens-induced ocular surface changes.
- Silicone hydrogel (Si-Hy) and scleral gas permeable (GP) contact lenses represent distinct categories of modern contact lens materials.
Purpose of the Study:
- To quantitatively compare the tear elimination rate (ER) under silicone hydrogel (Si-Hy) and scleral gas permeable (GP) contact lenses (CLs).
- To evaluate the impact of different CL types on tear film dynamics in wearers.
- To investigate potential correlations between CL design and tear exchange efficiency.
Main Methods:
- Recruitment of subjects successfully wearing well-fitting Si-Hy CLs or scleral GP CLs, many with irregular corneas.
- Objective measurement of tear ER using a fluorometer to track fluorescein isothiocyanate dextran dye signal decay.
- Calculation of ER in %/min from 5 to 30 minutes to mitigate reflex tearing effects, with specific measurements for scleral GP lenses during settling and later wear periods.
Main Results:
- Scleral GP CL wearers exhibited significantly lower average ER (0.57%/min and 0.42%/min) compared to non-CL wear (34.17%/min).
- Si-Hy CL wearers demonstrated a higher average ER of 6.09%/min.
- The ER under scleral GP lenses was significantly lower than under Si-Hy lenses for both settling and later wear periods (P < 0.001).
Conclusions:
- Well-fitted scleral GP contact lenses result in significantly reduced tear elimination rates compared to soft Si-Hy contact lenses.
- The observed lower ER under scleral GP lenses suggests improved tear film stability and reduced tear turnover.
- A slight increase in tear exchange during the initial settling period of scleral GP lenses may indicate dynamic changes in tear vault thickness.
Related Concept Videos
Gas Exchange and Transport
Physical Principles Governing Gas Exchange
Gas Laws Governing Respiration
The behavior of gases is guided by Dalton's Law of partial pressures and Henry's Law.
Dalton's Law asserts that the total...
Social Exchange Theory
Rigid Body Equilibrium Problems - I
Kinetic Molecular Theory and Gas Laws Explain Properties of Gas Molecules
Permeability of Concrete