Related Experiment Video
Updated: Feb 15, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Nanoparticle concentrations and composition in a dental office and dental laboratory: A pilot study on the influence
Andreja Lang1, Maja Ovsenik2, Ivan Verdenik3
1a Faculty of Medicine , University of Ljubljana , Ljubljana , Slovenia.
Abstract:
During material treatment in dentistry particles of different size are released in the air. To examine the degree of particle exposure, air scanning to dental employees was performed by the Scanning Mobility Particle Sizer. The size, shape and chemical composition of particles collected with a low-pressure impactor were determined by scanning electronic microscopy and X-ray dispersive analysis. The average concentrations of nanoparticles during working periods in a clean dental laboratory (45,000-56,000 particles/cm3), in an unclean dental laboratory (28,000-74,000 particles/cm3), and in a dental office (21,000-50,000 particles/cm3), were significantly higher compared to average concentrations during nonworking periods in the clean dental laboratory (11,000-24,000 particles/cm3), unclean laboratory (14,000-40,000 particles/cm3), and dental office (13,000-26,000 particles/cm3). Peak concentration of nanoparticles in work-intensive periods were found significantly higher (up to 773,000 particles/cm3), compared to the non-working periods (147,000 particles/cm3) and work-less intensive periods (365,000 particles/cm3). The highest mass concentration value ranged from 0.055-0.166 mg/m3. X-ray dispersive analysis confirmed the presence of carbon, potassium, oxygen, iron, aluminum, zinc, silicon, and phosphorus as integral elements of dental restorative materials in form of nanoparticle clusters, all smaller than 100 nm. We concluded that dental employees are exposed to nanoparticles in their working environment and are therefore potentially at risk for certain respiratory and systematic diseases.
Related Concept Videos
Pilot and Numeric Relaying
Concentration Cells
Consider the following voltaic cell:
Serum Laboratory Studies, Stool Test, Breath Test
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Solution Concentration and Dilution

