Related Experiment Video
Updated: Feb 15, 2026

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Diagnosis of breast cancer based on microcalcifications using grating-based phase contrast CT
Xinbin Li1,2, Hewei Gao3, Zhiqiang Chen4,5
1Department of Engineering Physics, Tsinghua University, Haidian District, Beijing, China.
Objectives:
Microcalcifications are an important feature in the diagnosis of breast cancer, especially in the early stages. In this paper, a CT-based method is proposed to potentially distinguish benign and malignant breast diseases based on the distributions of microcalcifications using grating-based phase-contrast imaging on a conventional X-ray tube.
Methods:
The method presented based on the ratio of dark-field signals to attenuation signals in CT images is compared with the existing method based on the ratio in projections, and the threshold for the classification of microcalcifications in the two types of breast diseases is obtained using our approach. The experiment was operated on paraffin-fixed specimens that originated from 20 female patients ranging from 27-65 years old.
Results:
Compared with the method based on projection images (AUC = 0.87), the proposed method is more effective (AUC = 0.95) to distinguish the two types of diseases. The discrimination threshold of microcalcifications for the classification of diseases in CT images is found to be 3.78 based on the Youden index.
Conclusions:
The proposed method can be further developed to improve the early diagnosis and diagnostic accuracy and reduce the clinical misdiagnosis rate of breast cancer.
Key Points:
• Microcalcifications are of special importance to indicate early breast cancer. • Grating-based phase-contrast imaging can improve the diagnosis of breast cancers. • The method described here can better classify benign and malignant breast diseases.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Acid-Base Titration Curves
For a titration carried out for 25.00 mL of...
Weak Base Solutions
Base Excision Repair
The first step of...

