Related Experiment Video
Updated: Feb 15, 2026

Development of a Direct Pulp-capping Model for the Evaluation of Pulpal Wound Healing and Reparative Dentin Formation in Mice
Published on: January 12, 2017
Microtensile bond strength of universal adhesives to flat versus Class I cavity dentin with pulpal pressure
Maja Lezaja Zebic1, Bojan Dzeletovic1, Vesna Miletic1
1DentalNet Research Group, School of Dental Medicine, University of Belgrade, Belgrade, Serbia.
Objectives:
The aim of this study was to test long-term microtensile bond strength (µTBS) of 2 universal adhesives applied to dentin following "total-etch" (TE) or "self-etch" (SE) protocols and aged by direct or indirect water exposure using simulated pulpal pressure.
Materials And Methods:
Single Bond Universal (SBU, 3M ESPE) or Ipera Bond (IP, Itena) were applied to mid-coronal dentin ("flat dentin") or Class I cavity ("cavity dentin") following TE or SE protocols in 112 extracted human third molars. Sixteen groups (n = 7 per group) were prepared, 8 groups for µTBS measurements after 24 hours, and further 8 groups for measurements after 6 months storage. "Cavity dentin" groups were subjected to simulated hydrostatic pulpal pressure of 15 cm H2 O using a custom-made device before cutting 1 × 1 mm sticks while "flat dentin" groups were cut into sticks and directly exposed to deionized water.
Results:
Generally, the TE protocol resulted in highest µTBS values on flat dentin initially for both adhesives (general linear model, P < .05). Long-term storage resulted in significantly lower µTBS values for the TE protocol (P < .05) while the SE protocol showed comparable values after 6 months (P > .05). "Cavity dentin" with simulated pulpal pressure resulted in lower µTBS than "flat dentin" (P < .05). For both adhesives, µTBS was in the range of 19-42 MPa initially and 16-36 MPa after 6 months storage.
Conclusions:
µTBS to dentin of universal adhesives is more stable in the long term following the SE than TE protocol. Simulated pulpal pressure and cavity-type sample preparation may be recommended for µTBS testing as a more clinically relevant strategy.
Clinical Significance:
Microtensile bond strength to dentin of universal adhesives appears more stable following the "self-etch" than "total-etch" protocol after long-term degradation. More clinically relevant data may be obtained using simulated pulpal pressure and cavity-type sample preparation in the study design.
Related Concept Videos
Bonding and Strength of Aggregate
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Bond Energies and Bond Lengths

