Related Experiment Video
Updated: Feb 15, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Computed Tomography Measurements as a Standard of Exophthalmos? Two-Dimensional Versus Three-Dimensional Techniques
Jie Guo1, Jiang Qian1, Yifei Yuan1
1a Department of Ophthalmology, Eye & ENT Hospital , Fudan University, Myopia Key Laboratory of Health Ministry , Shanghai , China.
Purpose:
To compare measurements of exophthalmos using two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) methods.
Methods:
The CT data of 50 patients with thyroid eye disease were collected. The exophthalmos measurements were performed using both 2D and 3D methods. The protrusion of the globe center, the deviation angle of the ocular axis, and the distance between the globe center and the corneal apex were also recorded. The agreements between Hertel exophthalmometry and different CT measurements were analyzed, and the geometrical relationship between the protrusion of the corneal apex and globe center were analyzed.
Results:
The measurement agreement from consecutive CT scans was significantly better using the 3D method than the 2D method (p < 0.05). The difference in exophthalmos measurements between the 2D and 3D methods was 0.9 ± 1.2 mm (p < 0.05), and the 3D exophthalmos measurement was more consistent with Hertel exophthalmometry. The exophthalmos of the corneal apex and the globe center agreed with the geometrical formula well. The location error between the corneal apexes marked on the 2D and 3D images was correlated with the vertical deviation angle of the ocular axis (r = 0.516).
Conclusion:
The reliability of CT measurements performed using a 3D method was better than those obtained using a conventional 2D method. The 3D measurements were also more consistent with the exophthalmometry results. The exophthalmos of the globe center might be considered an important reference for patients with severe strabismus.
More Related Videos
11:09Construction of a Realistic, Whole-Body, Three-Dimensional Equine Skeletal Model using Computed Tomography Data
Published on: February 25, 2021
09:37Extracting Metrics for Three-dimensional Root Systems: Volume and Surface Analysis from In-soil X-ray Computed Tomography Data
Published on: April 26, 2016
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Three-Dimensional Force System