Related Experiment Video
Updated: Feb 15, 2026

Exploring m6A and m5C Epitranscriptomes upon Viral Infection: an Example with HIV
Published on: March 5, 2022
High-sensitivity 5-, 6-, and 7-color PNH WBC assays for both Canto II and Navios platforms
D Robert Sutherland1, Fernando Ortiz2, Graeme Quest1
1Laboratory Medicine Program, Toronto General Hospital, Ontario, Canada.
Background:
Paroxysmal Nocturnal Hemoglobinuria (PNH) is a rare acquired hematopoietic stem cell disorder characterized by an inability to make Glyco-Phosphatidyl-Inositol (GPI)-linked cell surface structures. Fluorescent proaerolysin (FLAER-Alexa488) is increasingly used to detect GPI-deficient WBCs by flow cytometry. However, FLAER is not available in all countries and is expensive to obtain in others. An earlier study to compare FLAER-based and non-FLAER assays confirmed very good agreement between the two tubes suggesting a cost effective simultaneous evaluation of PNH neutrophils and monocytes is possible without FLAER.
Methods:
We have used a single tube approach with a 7-color assay comprising FLAER-CD157-CD15-CD64-CD24-CD14-CD45. Conjugates were carefully selected and validated so that stained samples could be analyzed on either 10-color Navios or 8-color FACSCanto II platforms. The 6-color (minus CD14) and 5-color (minus CD24 and CD14) versions were also developed and compared with our predicate clinical lab 5-color assay comprising FLAER-CD157PE-CD64ECD-CD15PC5-CD45PC7.
Results/Conclusions:
CD15-gated PNH neutrophil clone size was quantified using either FLAER and CD157, FLAER and CD24, or CD157 and CD24. CD64-gated PNH monocyte clone size was quantified using either FLAER and CD157, FLAER and CD14, or CD157 and CD14. Analysis of >40 PNH samples showed that the FLAER-based plots derive virtually identical data to the non-FLAER plot for neutrophils (R2 = 1) and monocytes (R2 = 0.9999) and that closely similar data can be acquired using both Canto II and Navios platforms with 7-, 6-, and 5-color versions of the assay. Assessment of non-PNH samples confirmed extremely low background rate of PNH phenotypes (neutrophils and monocytes) with all three approaches. © 2018 International Clinical Cytometry Society.
Related Concept Videos
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Color Vision
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Changes in Skin Color: Clinical Perspectives
Albinism
Albinism is a genetic disorder that affects (completely or partially) the coloring of skin, hair, and eyes. The defect is primarily...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...