Angular Stable Miniplate Fixation of Chronic Unstable Scaphoid Nonunion
Philip M J Schormans1, Peter R G Brink1, Martijn Poeze1
1Department of Trauma Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
Volar angular stable miniplate fixation with bone grafting successfully treated chronic scaphoid nonunion in 90% of patients. This method is effective even for long-standing cases and those with prior surgeries, aiding fracture healing.
Area of Science:
- Orthopedic Surgery
- Hand and Wrist Surgery
- Trauma Surgery
Background:
- Scaphoid nonunion occurs in 5-15% of fractures and poses treatment challenges.
- Healing scaphoid nonunion is crucial to prevent advanced collapse and osteoarthritis.
- Chronic scaphoid nonunion requires effective surgical solutions.
Purpose of the Study:
- To assess the feasibility of treating scaphoid nonunion with volar angular stable miniplate fixation and bone grafting.
- To evaluate the technique's success in patients with long-standing nonunion or previous surgical interventions.
- To hypothesize the technique's efficacy in achieving scaphoid union.
Main Methods:
- A prospective cohort study involving 21 patients with scaphoid nonunion.
- Radiological assessment of nonunion healing via CT scans at 3-month intervals.
- Functional outcomes measured by grip strength, range of motion, and PRWHE scores.
Main Results:
- 90% of patients (19/21) achieved radiological healing of the scaphoid nonunion.
- Functional outcomes showed a significant decrease in PRWHE scores by 34 points.
- Healing was achieved irrespective of nonunion duration (6-183 months) or prior surgery history.
Conclusions:
- Volar angular stable miniplate fixation with bone grafting is a successful treatment for chronic unstable scaphoid nonunion.
- The technique demonstrates efficacy in complex cases, including those with long-term nonunion and previous surgeries.
- Rotational interfragmentary stability may be a key factor in successful unstable scaphoid nonunion treatment.
Related Concept Videos
Angular Momentum
Angular Velocity and Displacement
Conservation of Angular Momentum
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...