A Biomechanical Comparison of Screw and Plate Fixations for Scaphoid Fractures
Jill Goodwin1, Paulo Castañeda1, Patricia Drace1
1Department of Orthopaedic Surgery, University of Arizona College of Medicine, Phoenix, Arizona.
Abstract:
Background Headless screw fixation is the current gold standard of surgical repair for scaphoid fractures. However, maintaining reduction of certain types of scaphoid fractures is challenging with a compression screw. Plate fixation may offer superior fixation in some scaphoid fractures, particularly those with comminution, nonunion, segmental bony defects, and osteopenic or osteoporotic bone. Purpose This study questions whether method of fixation is a determinant in load to failure in segmental scaphoid fractures, and whether any fixation provides a greater mechanical advantage in simulated normal versus osteoporotic bone. Materials and Methods Polyurethane models were fashioned to simulate scaphoids with 3-mm segmental defects. Defects were bridged by one of three constructs: a locking plate, a nonlocking plate, or a headless compression screw. Three models for each fixation construct were tested for both simulated normal and osteoporotic bone density. Load to failure was recorded as the load at which the 3-mm segmental defect was closed. Results Gap closure occurred in all trials. In simulated normal bone, there were no statistically significant differences in load to failure between fixation methods. In simulated osteoporotic bone, the locking plate had a 28% greater load to failure as compared with screw fixation. Conclusion While biomechanical testing shows that plate and screw fixations are equivalent in normal density bone for fixation of a segmental scaphoid defect, locking plates are superior to screw fixation in simulated osteoporotic bone models. Clinical Relevance Plate fixation may provide superior fixation for complex scaphoid fractures, particularly in osteopenic bone.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...