Soluble fibrin is a useful marker for predicting extracorporeal membrane oxygenation circuit exchange because of circuit clots
Related Experiment Video
Updated: Feb 15, 2026

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Kota Hoshino1, Kentaro Muranishi2, Yasumasa Kawano2
1Department of Emergency and Critical Care Medicine, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan. hoshinoqq@yahoo.co.jp.
Abstract:
A circuit clot is one of the most frequent complications during extracorporeal membrane oxygenation (ECMO) support. We identify coagulation/fibrinolysis markers for predicting ECMO circuit exchange because of circuit clots during ECMO support. Ten patients with acute pulmonary failure who underwent veno-venous ECMO were enrolled between January 2014 and December 2016. ECMO support lasted 106 days. The 6 days on which the ECMO circuits were exchanged were considered as circuit clot (+) group, while the remaining 100 days were considered as circuit clot (-) group. The predictors of ECMO circuit exchange because of circuit clots were identified. The mean duration of ECMO support was 10 ± 13 days, and the mean number of ECMO circuit exchange was 0.6 ± 1.1 times per patient. Thrombin-antithrombin complex (TAT) and soluble fibrin (SF) were higher in the circuit clot (+) group than in the circuit clot (-) group (both P < 0.01). According to a multivariate analysis, SF was the only independent predictor of ECMO circuit exchange (P < 0.01). The odds ratio (confidence intervals) for SF (10 µg/ml) was 1.20 (1.06-1.36). The area under the curve and optimal cut-off value were 0.95 and 101 ng/ml for SF (sensitivity, 100%; specificity, 89%). SF may be useful in predicting ECMO circuit exchange because of circuit clots.
Related Concept Videos
Second-Order Circuits
Input signals typically originate from voltage or current sources, with the output often representing voltage across the capacitor and/or current through the inductor. For example, in...
First-Order Circuits
One common example of a first-order circuit is the RC (resistor-capacitor) circuit. These circuits are used in relaxation oscillators such as neon lamp oscillator circuits. When voltage is...
The Y-to-Y Circuit
LC Circuits
Three-Phase Circuits
Neural Circuits
Neuronal pools are collections of nerve cells with similar functions and interact through chemical and electrical signals. These pools include both interneurons (the central neural circuit nodes that...