Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process
Bo Deng1, Yaoyao Shi2, Tao Yu2
1The Key Laboratory of Contemporary Design and Integrated Manufacturing Technology, Ministry of Education, Northwestern Polytechnical University, Xi'an 710072, China. dengbo1025@outlook.com.
Materials (Basel, Switzerland)
|February 1, 2018
Summary
Optimizing composite tape winding involves analyzing process parameters to enhance tensile strength and reduce void content. This study uses sensitivity analysis to find stable parameter ranges for reliable composite product manufacturing.
Area of Science:
- Materials Science
- Manufacturing Engineering
- Composite Materials
Background:
- Composite tape winding is key for high-quality composite products.
- Process parameters significantly impact mechanical properties (tensile strength) and defects (void content).
Purpose of the Study:
- To develop an integrated methodology for optimizing composite tape winding process parameters.
- To identify optimal parameter intervals for improved product performance and reduced defects.
Main Methods:
- Applied global multi-parameter sensitivity analysis to assess parameter influence.
- Utilized single-parameter sensitivity analysis to determine stability ranges.
- Combined both methods to establish comprehensive optimized intervals.
Main Results:
- Identified critical process parameters affecting tensile strength and void content.
- Distinguished between stable and unstable parameter ranges.
- Provided validated, optimized intervals for composite tape winding.
Conclusions:
- The integrated sensitivity analysis methodology effectively optimizes composite tape winding parameters.
- Optimized parameter intervals ensure reliable and stable manufacturing of winding products.
- This approach enhances the quality and performance of composite materials.
Keywords:
composite tape winding processinterval optimizationsensitivity analysistensile strengthvoid contentMore Related Videos
Related Concept Videos
Prediction Intervals
3.4K
The interval estimate of any variable is known as the prediction interval. It helps decide if a point estimate is dependable.
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
3.4K
Errors in Taping
366
Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
366
Three-Winding Transformers
733
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
733
Distance Measurements by Taping
489
Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
489
Taping Over Different Ground Profiles
411
Taping over varying ground profiles requires careful adaptation to achieve accurate measurements. On smooth, level ground with minimal vegetation, the tape can rest directly on the ground. Here, the taping team, typically consisting of a head and a rear tapeman, coordinates their positions with clear communication. The rear tapeman holds the tape at the starting point and guides the head tapeman toward a range pole placed beyond the endpoint, using hand or voice signals to ensure alignment.On...
411
Classifying Matter by Composition
91.8K
Matter: Pure Substances and Mixtures
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
91.8K