Related Experiment Video
Updated: Feb 15, 2026

Semi-automated Optical Heartbeat Analysis of Small Hearts
Published on: September 16, 2009
Semi-automated set-up for exhaustive micro-electromembrane extractions of basic drugs from biological fluids
Miloš Dvořák1, Knut Fredrik Seip2, Stig Pedersen-Bjergaard3
1Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic.
Abstract:
Manual handling of microliter volumes of samples and reagents is usually prone to errors and may have direct consequence on the overall performance of microextraction process. Direct connection of a syringe pump and a disposable microextraction unit using flexible polymeric tubing was employed for semi-automated liquid handling in micro-electromembrane extraction (μ-EME). A three-phase μ-EME system was formed by consecutive withdrawal of microliter volumes of donor solution, free liquid membrane (FLM) and acceptor solution into the unit. Excellent repeatability and accuracy of the withdrawal sequence was achieved for solution volumes typically used in μ-EME (1-5 μL) as well as excellent correlation between the initially withdrawn and the finally collected solution volumes. μ-EMEs were initiated by application of d.c. electric potential to the terminal aqueous solutions and specific μ-EME parameters were optimized in order to ensure complete transfer of model analytes from donor to acceptor solution. Exhaustive μ-EMEs of three basic drugs, nortriptyline, papaverine and haloperidol, were achieved from 1.3 μL of acidified donor solution (10 mM HCl) across 2.5 μL of FLM (1-ethyl-2-nitrobenzene) into 1.3 μL of acidified acceptor solution (25 mM HCl) in 10 min at 150 V. The three drugs were also exhaustively extracted from salt- and protein-containing standard solutions, human urine and human plasma with extraction recoveries ranging from 79 to 102%. Resulting acceptor solutions were analysed by capillary electrophoresis with ultraviolet detection (CE-UV) and the μ-EME-CE-UV method was characterized by good linearity (coefficients of determination ≥ 0.992), high repeatability (RSD values ≤ 6.5%) and limits of detection ≤ 0.15 mg/L.
Related Concept Videos
Factors Affecting Drug Biotransformation: Biological
Species differences: Variations in enzyme systems across species can cause disparities in drug metabolism. For instance, humans may metabolize certain drugs faster than rodents, altering therapeutic effects.
Strain differences: Genetic variations within a species can result in differing enzyme activity, impacting drug response and toxicity. For example, some mouse strains may...
Drug Products: Biologics, Biosimilars and Interchangeables
Energy Basics
VSEPR Theory and the Basic Shapes
What is Conservation Biology?
Basicity of Aliphatic Amines
To measure the basicity of amines, two conventions are generally used. The first defines Kb as the basicity constant for the deprotonation reaction of water by the amine, as presented in Figure 1. Conventionally, lower Kb indicates higher...