Related Experiment Video
Updated: Feb 15, 2026

Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation
Published on: July 15, 2015
Application of Acoustoelasticity to Evaluate Nonlinear Modulus in Ex Vivo Kidneys
Abstract:
Currently, dynamic elastography techniques estimate the linear elastic shear modulus of different body tissues. New methods that investigate other properties of soft tissues such as anisotropy, viscosity, and shear nonlinearity would provide more information about the structure and function of the tissue and might provide a better contrast than tissue stiffness and hence provide more effective diagnostic tools for some diseases. It has previously been shown that shear wave velocity in a medium changes due to an applied stress, a phenomenon called acoustoelasticity (AE). Applying a stress to compress a medium while measuring the shear wave velocity versus strain provides data with which the third-order nonlinear shear modulus can be estimated. To evaluate the feasibility of estimating , we evaluated ten ex vivo porcine kidneys embedded in 10% porcine gelatin to mimic the case of a transplanted kidney. Under assumptions of an elastic incompressible medium for AE measurements, the shear modulus was quantified at each compression level and the applied strain was assessed by measuring the change in the thickness of the kidney cortex. Finally, was calculated by applying the AE theory. Our results demonstrated that it is possible to estimate a nonlinear shear modulus by monitoring the changes in strain and due to kidney deformation. The magnitudes of are higher when the compression is performed progressively and when using a plate attached to the transducer. Nevertheless, the values obtained for are similar to those previously reported in the literature for breast tissue.
Related Concept Videos
Application of Nonlinear Inequalities
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Bulk Modulus
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Kidney Structure