Related Experiment Video
Updated: Feb 15, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Acute intraoperative echocardiographic changes after transapical off-pump mitral valve repair with NeoChord
Andrea Colli1, Laura Besola1, Matteo Montagner1
1Cardiac Surgery Unit, Department of Cardiac, Thoracic, and Vascular Sciences, University of Padua, Italy.
Objectives:
Our aim is to investigate the acute intraoperative effects of the NeoChord repair procedure on mitral valve (MV) annular geometry and LV function and the impact of these changes on MR at 1-year follow-up.
Background:
Recently transapical off-pump mitral valve repair with NeoChord implantation has been demonstrated to be safe and effective in patients with degenerative mitral regurgitation (DMR).
Methods:
We retrospectively analyzed baseline and early postoperative 3-dimensional transesophageal echocardiography of 66 patients who underwent NeoChord repair for isolated posterior leaflet MV disease using semiautomatic off-line analysis software.
Results:
We observed a significant acute reduction of indexed LV end diastolic volume (Δ% = 14, p < .001), LV ejection fraction (Δ = 5.7%, p = .002), indexed left atrial volume (Δ = 14.7%, p = .045), and pulmonary artery pressure (Δ = 2.1%, p = .026). Among MV geometric parameters, we observed a significant reduction of MV antero-posterior diameter (Δ = 7%, p < .001), sphericity index (Δ = 8%, p < .001), annulus circumference (Δ = 0.9%, p = .021), and annulus area (Δ = 2.7%, p = .018). At 1-year, 53 patients (85.5%) presented MR ≤ mild, while 9 patients (14.5%) had MR ≥ moderate. Reduction of AP diameter (OR = 0.14, CI -3.83; 0.08, p < .001), annulus circumference (OR = 0.27, CI -2.98; 0.37, p = .005), MV area (OR = 0.39, CI -2.46; 0.61, p = .04), aorto-mitral angle (OR = 0.38, CI -2.49; 0.54, p = .002) and iEDV (OR = 0.44, CI -2.44; 0.81, p = .001) were independent protective factors against recurrence of MR greater than mild at 1-year follow-up.
Conclusions:
Transapical NeoChord repair produces important acute intraoperative changes in MV anatomy in DMR patients. The acute changes observed were associated with procedure durability at 1-year FU.
More Related Videos
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Mismatch Repair
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Overview of DNA Repair
Chemically...

