A feasibility study of independent verification of dose calculation for Vero4DRT using a Clarkson-based algorithm
Mikiko Yamashita1, Ryo Takahashi2, Masaki Kokubo3
1Department of Radiological Technology, Kobe City Medical Center General Hospital, Hyogo 650-0047, Japan; Radiation Oncology Group, Institute of Biomedical Research and Innovation Laboratory, Hyogo 650-0047, Japan.
Abstract:
Dose verification for a gimbal-mounted image-guided radiotherapy system, Vero4DRT (Mitsubishi Heavy Industries Ltd., Tokyo, Japan) is usually carried out by pretreatment measurement. Independent verification calculations using Monte Carlo methods for Vero4DRT have been published. As the Clarkson method is faster and easier to use than measurement and Monte Carlo methods, we evaluated the accuracy of an independent calculation verification program and its feasibility as a secondary check for Vero4DRT. Computed tomography (CT)-based dose calculation was performed using a modified Clarkson-based algorithm. In this study, 120 patients' treatment plans were collected in our institute. The treatments were performed using conventional irradiation for lung and prostate, 3-dimensional (3D) conformal stereotactic body radiotherapy (SBRT) for the lung, and intensity-modulated radiation therapy (IMRT) for the prostate. Differences between the treatment planning system (TPS) and the Clarkson-based independent dose verification software were computed, and confidence limits (CLs, mean ± 2 standard deviation %) for Vero4DRT were compared with the CLs for the C-arms linear accelerators in the previous study. The results of the CLs, the conventional irradiation, SBRT, and IMRT showed 2.2 ± 3.5% (CL of the C-arms linear accelerators: 2.4 ± 5.3%), 1.1 ± 1.7% (-0.3 ± 2.0%), 4.8 ± 3.7% (5.4 ± 5.3%), and -0.5 ± 2.5% (-0.1 ± 3.6%) differences, respectively. The dose disagreement between the TPS and CT-based independent dose verification software was less than the 5% action level of American Association of Physicists in Medicine (AAPM) Task Group 114 (TG114). The CLs for the gimbal-mounted Vero4DRT were similar to the deviations for C-arms linear accelerators.
More Related Videos
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strategies of Self-Presentation II: Self-Verification
Bioavailability Study Design: Single Versus Multiple Dose Studies
Introduction to Test of Independence
The test statistic for a test of independence is similar to that of a goodness-of-fit test: