Related Experiment Video
Updated: Feb 15, 2026

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Differentiation between radiation-induced brain injury and glioma recurrence using 3D pCASL and dynamic
Yu-Lin Wang1, Si Chen1, Hua-Feng Xiao1
1Department of Radiology, People's Liberation Army General Hospital, China.
Purpose:
This study was performed to validate the efficacy of three-dimensional pseudocontinuous arterial spin labeling (pCASL) compared with dynamic susceptibility contrast-enhanced perfusion-weighted imaging (DSC-PWI) in distinguishing radiation-induced brain injury from glioma recurrence in patients with glioma.
Methods:
Both 3D pCASL and DSC-PWI were performed using a 3.0 Tesla scanner in 69 patients with previously resected and irradiated glioma who displayed newly developed abnormal contrast-enhanced lesions. The included patients were classified into a radiation-induced brain injury group (n = 34) and a glioma recurrence group (n = 35) based on subsequent pathologic analysis or clinical-radiological follow-up. Lesion perfusion parameter values (CBF and nCBF on pCASL, nrCBV and nrCBF on DSC-PWI) were measured and compared between the two groups using Student's t test. Pearson correlation analysis was performed to evaluate the correlation between pCASL (CBF and nCBF) and DSC-PWI (nrCBV and nrCBF) values in the contrast-enhanced lesions and in the perifocal edema regions.
Results:
For the contrast-enhanced lesions, the CBF, nCBF, nrCBV, and nrCBF (29.46 ± 15.08 ml/100 g/min, 1.11 ± 0.50, 1.39 ± 1.15, and 1.30 ± 0.74) in the radiation-induced brain injury group were significantly lower than those (64.52 ± 33.92 ml/100 g/min, 2.73 ± 1.71, 3.39 ± 2.12, and 3.20 ± 1.95) in the glioma recurrence group (P < 0.001). The CBF and nCBF demonstrated strong correlation with nrCBV and nrCBF in the contrast-enhanced lesions.
Conclusion:
Radiation-induced brain injury and glioma recurrence can be reliably distinguished using both 3D pCASL and DSC-PWI. Contrast-free 3D pCASL is a suitable alternative to DSC-PWI for long-term follow-up in glioma patients with postoperative radiotherapy.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Biological Effects of Radiation
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Radiation: Applications
The average...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...

