How to Build a Laser Speckle Contrast Imaging LSCI System to Monitor Blood Flow
Published on: November 11, 2010
Association Between Optic Nerve Head Blood Flow Measured Using Laser Speckle Flowgraphy and Radial Arterial Pressure
Hironobu Hayashi1, Masahiro Okamoto2, Hideaki Kawanishi3
1Department of Anesthesiology, Nara Medical University, Nara, Japan.
Objective:
This study was designed to investigate the association between ocular blood flow measured using laser speckle flowgraphy (LSFG) and radial arterial pressure during aortic arch surgery.
Design:
A prospective study.
Setting:
A single university hospital.
Participants:
This study included 24 patients undergoing aortic arch surgery with cardiopulmonary bypass (CPB) using antegrade selective cerebral perfusion (SCP).
Interventions:
Measurement of optic nerve head blood flow using LSFG and radial arterial pressure via a catheter in the radial artery METHODS AND MAIN RESULTS: Antegrade SCP was managed with 24℃ and 40-to-60 mmHg at the right radial artery, which usually corresponds to a flow rate of 10 mL/kg/min. Optic nerve head blood flow using LSFG and radial arterial blood pressure were evaluated simultaneously at the right side and recorded at the following 4 points: after the induction of anesthesia (phase 1), after the beginning of CPB (phase 2), after the beginning of antegrade SCP (phase 3), and after cessation of CPB (phase 4). A moderate positive correlation between %change of mean blur rate in the optic nerve head measured using LSFG and %change of radial mean arterial pressure was identified (r = 0.604, p < 0.001). Bland-Altman analysis showed that the bias (mean difference) was -1.2% (95% limits of agreement -47.4% to 45.0%), indicating good agreement between %changes of the values recorded using the 2 measurements.
Conclusions:
Intraoperative monitoring of optic nerve head blood flow using LSFG can be used as an additional cerebral perfusion parameter during aortic arch surgery with CPB using antegrade SCP.
More Related Videos
06:24Paired Cisterna Magna Nanoinjection and Laser Speckle Contrast Imaging Assay to Study Cerebral Blood Flow Regulation In Vivo
Published on: July 8, 2025
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)