Implantable loop recorders in patients with unexplained syncope: Clinical predictors of pacemaker implantation
Martin Huemer1, Ann-Kristin Becker1, Alexander Wutzler1
1Department of Cardiology, Campus Virchow-Klinikum, Charité - University Medicine Berlin, Germany.
Background:
Implantable loop recorders (ILR) are a valuable tool for the investigation of unexplainedsyncopal episodes. The aim of this retrospective single center study was to identify predictive factors for pacemaker implantation in patients with unexplained syncope who underwent ILR insertion.
Methods:
One hundred six patients were retrospectively analyzed (mean age 59.1 years; 47.2% male) with unexplained syncope and negative conventional testing who underwent ILR implantation. The pri- mary study endpoint was detection of symptomatic or asymptomatic bradycardia requiring pacemaker implantation.
Results:
The average follow-up period after ILR implantation was 20 ± 15 months. Pacemaker im- plantation according to current guidelines was necessary in 22 (20.8%) patients, mean duration until index bradycardia was 81 ± 88 (2-350) days. Ten (45.5%) patients received a pacemaker due to sinus arrest, 7 (31.8%) patients due to third-degree atrioventricular block, 2 (9.1%) patients due to second- degree atrioventricular block and 1 (4.5%) patient due to atrial fibrillation with a slow ventricular rate. Three factors remained significant in multivariate analysis: obesity, which defined by a body mass index above 30 kg/m2 (OR: 7.39, p = 0.014), a right bundle branch block (OR: 9.40, p = 0.023) and chronic renal failure as defined by a glomerular filtration rate of less than 60 mL/min (OR: 6.42, p = 0.035).
Conclusions:
Bradycardia is a frequent finding in patients undergoing ILR implantation due to un- explained syncope. Obesity, right bundle branch block and chronic renal failure are independent clinical predictors of pacemaker implantation.
Related Concept Videos
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Feedback Loops
Data Reporting and Recording
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Positive and Negative Feedback Loops
Cell Signaling Feedback Loops
Negative feedback loops
Most signaling systems have negative feedback loops that can perform different functions such as output limiter, and adaptation.
Output limiter
Upon receiving an input signal, the cellular response rapidly increases until a threshold is reached. Beyond this threshold, a negative feedback loop...