Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Eco-friendly Photoluminescent Textile Authentication with Curcumin
Published on: December 22, 2023
Simultaneous determination of three curcuminoids in Curcuma longa L. by high performance liquid chromatography
Yuling Long1, Wenpeng Zhang1, Fang Wang1
1Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Wuhan University, Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan 430071, China.
Abstract:
A novel method for analysis of three active components curcumin, demethoxycurcumin and bisdemethoxycurcumin in Curcuma longa L. was developed by HPLC coupled with electrochemical detection. Three curcuminoids were well separated on a C18 column and detected with high sensitivity. A mobile phase containing acetonitrile and 10 mM Na2HPO4-H3PO4 (pH 5.0) (50:50, v/v) was used. Good linearity was obtained in the range of 0.208-41.6, 0.197-39.4, and 0.227-114 μM for curcumin, demethoxycurcumin and bisdemethoxycurcumin respectively. The limit of detection reached up to 10-8 M, which was lower than that by UV detection. The relative standard deviations (RSDs) ranged from 1.06% to 1.88% for intra-day precision and from 4.30% to 5.79% for inter-day precision, respectively. The proposed method has been applied in real herb sample and recoveries ranging from 86.3% to 111% were obtained.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...