Motion Correction in Proton Resonance Frequency-based Thermometry in the Liver
Urte Kägebein1,2, Oliver Speck1,2, Frank Wacker2,3
1Biomedical Magnetic Resonance, Otto-von-Guericke University.
Magnetic resonance imaging enables noninvasive temperature monitoring during procedures like ablation. New methods are improving motion-corrected proton resonance frequency (PRF) thermometry for moving organs, like the liver, to enhance treatment accuracy.
Area of Science:
- Medical Imaging
- Biophysics
- Interventional Radiology
Background:
- Magnetic resonance imaging (MRI) offers noninvasive, in vivo temperature measurement capabilities.
- Proton resonance frequency (PRF) thermometry is a key MRI technique for monitoring thermal interventions.
- Motion sensitivity limits PRF thermometry in moving organs, hindering clinical application in areas like the liver.
Purpose of the Study:
- To review and summarize advancements in motion-corrected thermometry for the liver.
- To provide an overview of PRF thermometry principles and challenges.
- To discuss various motion correction strategies for liver applications.
Main Methods:
- Introduction to the physical principles of PRF thermometry.
- Discussion of challenges including fat phase modulation and magnetic field drifts.
- Categorization of motion correction methods: general compensation, library-based, referenceless, and hybrid approaches.
Main Results:
- Several developments indicate that motion-corrected thermometry in the liver is becoming achievable.
- Diverse attempts to correct thermometry in the liver are presented.
- The article outlines different categories of motion correction techniques.
Conclusions:
- Motion-corrected thermometry holds promise for real-time monitoring of interventional procedures in the liver.
- Further clinical validation in larger patient groups is required.
- The ultimate goal is to achieve complete liver tumor ablation using accurate, motion-corrected thermometry.
More Related Videos
08:29Measuring Liver Mitochondrial Oxygen Consumption and Proton Leak Kinetics to Estimate Mitochondrial Respiration in Holstein Dairy Cattle
Published on: November 30, 2018
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
Related Concept Videos
Resonance
Distance Corrections
Power Factor Correction
Frequency-dependent Selection
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...