Related Experiment Video
Updated: Feb 14, 2026

A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
Published on: April 21, 2017
Comparison of Self-Report Versus Sensor-Based Methods for Measuring the Amount of Upper Limb Activity Outside the
Kimberly J Waddell1, Catherine E Lang2
1Program in Physical Therapy, Washington University, St Louis, MO.
Objective:
To compare self-reported with sensor-measured upper limb (UL) performance in daily life for individuals with chronic (≥6mo) UL paresis poststroke.
Design:
Secondary analysis of participants enrolled in a phase II randomized, parallel, dose-response UL movement trial. This analysis compared the accuracy and consistency between self-reported UL performance and sensor-measured UL performance at baseline and immediately post an 8-week intensive UL task-specific intervention.
Setting:
Outpatient rehabilitation.
Participants:
Community-dwelling individuals with chronic (≥6mo) UL paresis poststroke (N=64).
Interventions:
Not applicable.
Main Outcome Measures:
Motor Activity Log amount of use scale and the sensor-derived use ratio from wrist-worn accelerometers.
Results:
There was a high degree of variability between self-reported UL performance and the sensor-derived use ratio. Using sensor-based values as a reference, 3 distinct categories were identified: accurate reporters (reporting difference ±0.1), overreporters (difference >0.1), and underreporters (difference <-0.1). Five of 64 participants accurately self-reported UL performance at baseline and postintervention. Over half of participants (52%) switched categories from pre-to postintervention (eg, moved from underreporting preintervention to overreporting postintervention). For the consistent reporters, no participant characteristics were found to influence whether someone over- or underreported performance compared with sensor-based assessment.
Conclusions:
Participants did not consistently or accurately self-report UL performance when compared with the sensor-derived use ratio. Although self-report and sensor-based assessments are moderately associated and appear similar conceptually, these results suggest self-reported UL performance is often not consistent with sensor-measured performance and the measures cannot be used interchangeably.
More Related Videos
07:42A Simple Non-invasive Method for Temporary Knockdown of Upper Limb Proprioception
Published on: March 3, 2018
04:49Author Spotlight: Enhancing Post-Stroke Upper Limb Rehabilitation with Robotic Technologies for Improved Motor Recovery and Functional Outcomes
Published on: September 6, 2024
Related Concept Videos
Arteries of the Upper Limbs
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Bones of the Upper Limb: Humerus
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
The Sense of Self: Reflected Self-Appraisal and Social Comparison