Computer tomography-based morphometric analysis of the cervical spine pedicles C3-C7
Leonard Westermann1, Carolin Spemes1, Peer Eysel1
1Centre of Orthopedic and Trauma Surgery, University Medical Centre, Kerpener Str. 62, 50937, Cologne, Germany.
Cervical pedicle dimensions vary by sex, with females having smaller pedicle width and length. These findings highlight potential risks for cervical pedicle screw insertion in a significant patient percentage.
Area of Science:
- Orthopedic Surgery
- Radiology
- Anatomy
Background:
- Cervical pedicle dimensions are crucial for safe screw placement.
- Understanding morphometric variations is essential for surgical planning.
Purpose of the Study:
- To analyze specific cervical pedicle dimensions in a large Caucasian cohort.
- To provide detailed morphometric data for preoperative planning of cervical pedicle screw insertion.
Main Methods:
- Retrospective analysis of 100 cervical spine CT scans (1mm slice thickness).
- Measurement of pedicle axial length (PAL), inner/outer pedicle diameter (IPD/OPD), angles (PSA/PTA), height (PH), width (PW), and cortical thickness (COT).
- Measurements performed by two independent observers on 1000 cervical pedicles (C3-C7) from 52 males and 48 females.
Main Results:
- Pedicle width (PW) and length (PAL) were smaller in females than males.
- Significant differences in cortical thickness between medial and lateral pedicle margins.
- Interrater reliability was good to very good for most measured parameters, except PAL and cortical thickness.
Conclusions:
- Cervical pedicle dimensions in this cohort are comparable to other ethnicities.
- Preoperative planning using fine-cut CT scans shows good reliability for surgical dimensions.
- A notable percentage of patients, particularly females at C3, may have pedicle widths unsuitable for safe screw insertion.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Qualitative Analysis
For instance, group IV...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...