Abstract:
On-site sampling is an analytical approach that can ensure the accuracy of monitoring data and enhance the effectiveness of environmental protection measures. In the present work, an in-syringe solid-phase extraction (SPE) device was designed for on-site sampling of trace contaminants in environmental water samples followed by gas chromatography-mass spectrometry (GC-MS) analysis. Template assisted freeze casting followed by hydrazine vapor reduction approach was used to synthesize a hierarchical porous graphene aerogel (HPGA), which was used as the sorbent in the in-syringe SPE device. Environmental degradable pyrethroids were selected as the model analytes. Owing to the large specific surface area and hydrophobicity of HPGA, the target molecules could be completely extracted during one aspirating/dispensing cycle. The analytes were stable on the sorbent for at least 72 h when the device was stored under airtight and light-free conditions, and were not affected by the pH value of sample solution. All results demonstrated that the device could meet the requirements of on-site sampling. For practical application, the limits of detection were found to be in the range of 0.012-0.11 ng mL-1 under the optimized conditions, and satisfactory recoveries in the range of 65.7-105.9% were obtained for the analysis of real samples. The results of this study demonstrate the immense potential of HPGA for the enrichment of trace environmental pollutants, and meanwhile promote the application of the in-syringe SPE technique as a promising candidate for on-site sampling.
More Related Videos
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Sampling Theorem
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....
Sampling Distribution