Polymerization efficiency affects interfacial fracture toughness of adhesives
Pong Pongprueksa1, Jan De Munck2, Masanao Inokoshi3
1KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7, blok a - bus 7001, B-3000 Leuven, Belgium; Mahidol University, Faculty of Dentistry, Department of Operative Dentistry and Endodontics, 6 Yothi Road, Ratchathewi, Bangkok 10400, Thailand.
Objective:
To evaluate the effect of the kind and concentration of photo-initiator on the degree of conversion (DC) of adhesives on dentin/glass substrates and their mini-interfacial fracture toughness (mini-iFT) to dentin.
Methods:
We tested the adhesive Clearfil S3 Bond Plus and 4 derived experimental 'LUB' ('Leuven Univesity Bond') adhesives (all from Kuraray Noritake), namely 'LUB-CQ/amine_high', 'LUB-CQ/amine_low', 'LUB-TPO_high', and 'LUB-TPO_low', respectively containing 2.0wt% camphorquinone (CQ) and 2.0wt% EDMAB (amine), 0.35wt% CQ and 0.35wt% amine, 2.0wt% TPO, and 0.35wt% TPO. For DC, each adhesive was applied onto glass or dentin prior to being cured (Bluephase 20i; Ivoclar Vivadent: "high mode") for 10s. DC was measured at 5min, 10min, 1h, 24h and 1 week using micro-Raman spectroscopy (SENTERRA; BrukerOptik). For mini-iFT, each adhesive was bonded to 320-grit SiC-paper ground dentin and covered with composite (Z100; 3M ESPE). The restored teeth were cut in sticks (1.5×2.0×16mm), after which a single-gradient notch was prepared at the adhesive-dentin interface using a 150-μm diamond blade. The micro-specimens were loaded until failure in a 4-point bending test and the mini-iFT in term of KQvM was calculated.
Results:
DC was higher on dentin than on glass. All adhesives were adequately polymerized at 1 week, except for LUB-TPO_low. DC at 5min was significantly higher for LUB-TPO_high than for both CQ/amine-based adhesives. The highest and most reliable mini-iFT was measured for LUB-CQ/amine_high, despite its 5-min DC was relatively low. No correlation between DC and mini-iFT was found.
Significance:
Curing of TPO-based adhesives is faster, but the dark cure of the CQ/amine-containing adhesives is more efficient. The differences in curing profiles do affect the mechanical properties of the resultant interfaces at dentin.
More Related Videos
Related Concept Videos
Toughness and Hardness of Aggregate
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Interfacial Electrochemical Methods: Overview
Olefin Metathesis Polymerization: Ring-Opening Metathesis Polymerization (ROMP)
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Actin Polymerization
The nucleation phase involves forming a stable nucleus consisting of three actin monomers to form a new actin filament. Actin-binding proteins such as formins and Arp2/3 complex help filament growth post-nucleation. The Formins form straight...