Measurement of Carpal Alignment Indices Using 3-Dimensional Computed Tomography
Ki Won Lee1, Joo Yul Bae1, Dong-Kyo Seo1
1Department of Orthopaedic Surgery, Gangneung Asan Hospital, Ulsan University College of Medicine, Gangneung, Korea.
Purpose:
This study aimed to establish normal values for wrist carpal alignment measured by 3-dimensional computed tomography (CT) and to show the inter- and intraobserver reliability of this measurement compared with simple radiography.
Methods:
The study utilized 3-dimensional CT and simple radiography of wrist joints in 30 asymptomatic volunteers. The wrist position was standardized using a custom-designed positioning device. Three independent observers measured carpal alignment parameters including distal radius articular angle, radiolunate angle, radioscaphoid angle, radiocapitate angle, radius-third metacarpal angle, scapholunate angle, lunocapitate angle, and lunate-third metacarpal angle.
Results:
Based on 3-dimensional CT measurement, the mean values of these parameters were: 12.9° ± 1.8° for the distal radius articular angle; 1.2° ± 3.8° for the radiolunate angle; 54.2° ± 5.6° for the radioscaphoid angle; 1.9° ± 2.2° for the radiocapitate angle; -1.0° ± 2.5° for the radius-third metacarpal angle; 52.9° ± 6.9° for the scapholunate angle; 0.7° ± 4.1° for the lunocapitate angle; -2.3° ± 4.6° for the lunate-third metacarpal angle. All parameters showed high inter- and intraobserver reliability in the 2 modalities.
Conclusions:
The normal values and ranges for carpal alignment angles were evaluated by using 3-dimensional CT. We could obtain high reliability in 3-dimensional CT as well as plain radiograph for the measurement of carpal alignment.
Type Of Study/Level Of Evidence:
Diagnostic II.
More Related Videos
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Indicators
Imaging Studies III: Computed Tomography
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Design Example: Alignment of a Road Line Using GIS
Mechanical Ventilation I: Indication and Settings