Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Comparative evaluation of effect of rotary and reciprocating single-file systems on pericervical dentin: A cone-beam
Priyanka Ramdas Zinge1, Jayaprakash Patil1
1Department of Conservative Dentistry and Endodontics, PMNM Dental College and Hospital, Bagalkot, Karnataka, India.
Aim And Objective:
The aim of this study is to evaluate and compare the effect of one shape, Neolix rotary single-file systems and WaveOne, Reciproc reciprocating single-file systems on pericervical dentin (PCD) using cone-beam computed tomography (CBCT).
Materials And Methods:
A total of 40 freshly extracted mandibular premolars were collected and divided into two groups, namely, Group A - Rotary: A1 - Neolix and A2 - OneShape and Group B - Reciprocating: B1 - WaveOne and B2 - Reciproc. Preoperative scans of each were taken followed by conventional access cavity preparation and working length determination with 10-k file. Instrumentation of the canal was done according to the respective file system, and postinstrumentation CBCT scans of teeth were obtained. 90 μm thick slices were obtained 4 mm apical and coronal to the cementoenamel junction. The PCD thickness was calculated as the shortest distance from the canal outline to the closest adjacent root surface, which was measured in four surfaces, i.e., facial, lingual, mesial, and distal for all the groups in the two obtained scans.
Results:
There was no significant difference found between rotary single-file systems and reciprocating single-file systems in their effect on PCD, but in Group B2, there was most significant loss of tooth structure in the mesial, lingual, and distal surface (P < 0.05).
Conclusion:
Reciproc single-file system removes more PCD as compared to other experimental groups, whereas Neolix single file system had the least effect on PCD.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Comparative Excretory Systems
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Factors Influencing Attraction IV: Reciprocity