Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during
Zhanqi Zhao1,2,3, Wei Wang4,3, Zuojing Zhang4
1Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, People's Republic of China.
Objective:
The aim of the study was to explore the feasibility of titrating tidal volume (V T) and positive end-expiratory pressure (PEEP) during one-lung ventilation (OLV) based on ventilation distribution and oxygenation.
Approach:
Twenty-four consecutive patients requiring intubation with a double-lumen tube and subsequent OLV for thoracic surgical procedures were examined prospectively in lateral posture. Electrical impedance tomography (EIT), blood gases, respiratory mechanics were successfully measured in 21 patients at various combinations of V T (4 ml kg-1, 6 ml kg-1, 8 ml kg-1 body weight) and PEEP (0 cm H2O, 4 cm H2O, 8 cm H2O) during OLV.
Main Results:
Low V T and low PEEP resulted in low global respiratory system compliance (C rs). Arterial partial pressure of O2 (PaO2) decreased with falling V T. Regional C rs measured with EIT showed high values at high V T and high PEEP in all but two patients. Regional C rs in mid and most dependent regions indicated tidal recruitment/derecruitment in eight patients at 8 ml kg-1 of V T and 4 cm H2O of PEEP; in four patients at 8 ml kg-1 and 0 cm H2O; in one patient at 6 ml kg-1 and 8 cm H2O. The changes in regional C rs induced by decreasing PEEP from 8 to 4 cm H2O were much smaller than those from 4 to 0 cm H2O. Ventilation distribution was most inhomogeneous with V T of 8 ml kg-1. All measures differed significantly among various V T and PEEP steps (p < 0.05).
Significance:
By using EIT in combination with PaO2, it is feasible to titrate V T and PEEP at the bedside during OLV.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings