Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Single-Molecule Surface-Enhanced Raman Scattering Measurements Enabled by Plasmonic DNA Origami Nanoantennas
Published on: July 21, 2023
Nanocavity-in-Multiple Nanogap Plasmonic Coupling Effects from Vertical Sandwich-Like Au@Al2O3@Au Arrays for
Chen Yang1, Ying Chen1, Dan Liu1
1Institute for Frontier Materials , Deakin University , Locked Bag 2000 , Geelong , Victoria 3220 , Australia.
Abstract:
The development of ideal three-dimensional (3D) tailorable surface-enhanced Raman scattering (SERS) substrates with the properties of timesaving, large area, high throughput, single or few molecules detection, reproducibility, reusable ability, and high density of "hot spots" has been the mainstream challenge and the robust task. Here, we construct perpendicular sandwich-like Au@Al2O3@Au hybrid nanosheets (PSHNs) on the Al foil as a 3D flexible substrate for SERS. The design of 3D PSHNs incorporates several advantageous aspects for SERS to enhance the performance of plasmonic diamers via bifunctions of vertical Al2O3 nanosheets (NSs) including the nanoscaffold and nanobaffle plate effects. As a nanoscaffold, it increases the space utilization of Au-Au diamers, whereas as a nanobaffle, it forms densely homogeneous Au@Al2O3@Au nanojunctions by sub-4 nm thickness of Al2O3 NSs as the dielectric isolated layer for the double-sided exposure of slitlike surface plasmon resonance. The optimized PSHN substrate exhibits a fascinating SERS sensitivity with an experimental enhancement factor of 1012 and is able to detect rhodamine B at an extremely low concentration up to the limit of single or few molecules (10-18 M), as well as can be recycled without the loss of SERS enhancement via the simple impregnation process. These advantages will greatly facilitate the wider use of SERS in many fields.
Related Concept Videos
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Vertical Curve: Problem Solving
Introduction to Vertical Curves
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
Scatter Plot

