Related Experiment Video
Updated: Feb 14, 2026

Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
Poly-L-Arginine-Modified Boron-Doped Diamond and Glassy Carbon Electrodes for Terbutaline Sulfate Detection
Paulo Vinicius F da Costa1, Rejane Maria P da Silva1, Hugo B Suffredini1
1Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580, Santo André, SP, Brazil.
Abstract:
This work describes the electro polymerization of a poly-L-arginine film onto boron-doped diamond (BDD) electrode and glassy carbon electrode (GCE) surfaces. The morphological and electrochemical properties of the modified electrodes were studied by atomic force microscopy and electrochemical methods, and their potential for terbutaline sulfate (TBS) detection was determined by voltammetry and chronoamperometry techniques. Our results demonstrate that the electrochemical surface area of both uncoated-bare electrodes (GCE e BDD) did not have significant differences in performance. However, higher current observed for TBS at poly-arginine/GCE is probably due to the higher surface coverage poly-arginine at GCE than BDD. It was concluded that for the systems under study, the poly-L-arginine/GCE was more suitable for TBS detection than that by the poly-L-arginine/BDD electrode, due to the more continuous and thicker poly-L-arginine film formed on the GCE, as revealed by the microscopy images. The TBS sensitivity and detection limit of the poly-L-arginine/GCE were determined to be 0.9 ±0.1 μA μmol-1L cm-2 and 0.10 μmol L-1, respectively, by chronoamperometry. Furthermore, the abilities of the electrodes to detect other β-agonists, namely clenbuterol and salbutamol, were studied by performing electrochemical experiments in the presence of these analytes. The results suggest that this film is a promising material for TBS detection due to high-surface-area electrochemical electrodes, and for the electrostatically-controlled thin film interference filter.
More Related Videos
Related Concept Videos
Sulfate Attack on Concrete
Sulfates from sources like soil, groundwater, or industrial effluents...
The Carbon Cycle
Carbon Skeletons
Standard Electrode Potentials
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...

