Related Experiment Video
Updated: Feb 14, 2026

The Innovation Arena: A Method for Comparing Innovative Problem-Solving Across Groups
Published on: May 13, 2022
An innovative paradigm of methods in microRNAs detection: highlighting DNAzymes, the illuminators
Mojdeh Mahdiannasser1, Zahra Karami2
1Department of Biology, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman, Iran; Department of Medical Genetics, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Abstract:
miRNAs are short regulatory sequences that monitor gene expression at post-transcriptional level. miRNAs play outstanding roles in cellular processes and their altered expression or aberrant function has been reported in diseases such as cancer. Furthermore, some of them serve as biomarkers for prognosis, diagnosis, and prediction of drug effectiveness as well as probable utility in the field of personalized medicine. As a result, proper and sensitive detection of miRNAs is a crucial matter. Traditional approaches including Northern blotting, Microarray, and Quantitative reverse transcription polymerase chain reaction have been extensively employed by means of miRNA detection for decades. However, these methods lack sufficient sensitivity, specificity and are labor intensive. In the recent years, DNAzyme-based assays have become strikingly attractive. The principal element in these techniques is a G-rich sequence, called the G-quadruplex, which turns into a DNAzyme with catalytic activity by addition of hemin, and subsequently allows simple and rapid detection of the target. In this review, different methods of miRNA detection, along with related advantages and disadvantages are discussed, with a special focus on DNAzymes and DNAzyme-derived methods.
Related Concept Videos
MicroRNAs
MicroRNAs
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Detection of Gross Error: The Q Test
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...

