An innovative paradigm of methods in microRNAs detection: highlighting DNAzymes, the illuminators

Mojdeh Mahdiannasser1, Zahra Karami2

  • 1Department of Biology, Faculty of Sciences, Shahid Bahonar University of Kerman, Kerman, Iran; Department of Medical Genetics, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.

Biosensors & Bioelectronics
|February 19, 2018
PubMed

Related Concept Videos

MicroRNAs01:22

MicroRNAs

MicroRNA (miRNA) are short, regulatory RNA transcribed from introns—non-coding regions of a gene—or intergenic regions—stretches of DNA present between genes. Several processing steps are required to form biologically active, mature miRNA. The initial transcript, called primary miRNA (pri-mRNA), base-pairs with itself forming a stem-loop structure. Within the nucleus, an endonuclease enzyme, called Drosha, shortens the stem-loop structure into hairpin-shaped pre-miRNA. After...
24.3K
MicroRNAs01:22

MicroRNAs

MicroRNA (miRNA) are short, regulatory RNA transcribed from introns (non-coding regions of a gene) or intergenic regions (stretches of DNA present between genes). Several processing steps are required to form biologically active, mature miRNA. The initial transcript, called primary miRNA (pri-mRNA), base-pairs with itself, forming a stem-loop structure. Within the nucleus, an endonuclease enzyme, called Drosha, shortens the stem-loop structure into hairpin-shaped pre-miRNA. After the pre-miRNA...
4.1K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
669
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.1K
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.1K
Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
23.8K