Related Experiment Video
Updated: Feb 14, 2026

Production and Targeting of Monovalent Quantum Dots
Published on: October 23, 2014
Strong Electrochemiluminescence from MOF Accelerator Enriched Quantum Dots for Enhanced Sensing of Trace cTnI
Xia Yang1, Yan-Qing Yu1, Ling-Zhi Peng1
1Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering , Southwest University , Chongqing 400715 , P.R. China.
Abstract:
The development of a sensitive and practical electrochemiluminescence (ECL) bioassay relies on the use of ECL signal tags whose signal intensity is high and stable. In this work, strong ECL emission was achieved from metal organic framework (MOF) accelerator enriched quantum dots (CdTe), which were applied as an efficient ECL signal tag for trace biomarker detection. It is particularly noteworthy that a novel mechanism to drastically enhance the ECL intensity of CdTe is established because isoreticular metal organic framework-3 (IRMOF-3) with 2-amino terephthalic acid (2-NH2-BDC) as the organic ligand not only allows for loading a large amount of CdTe via the encapsulating effect and internal/external decoration but also functions as a novel coreactant accelerator for promoting the conversion of coreactant S2O82- into the sulfate radical anion (SO4•-), further boosting the ECL emission of CdTe. On the basis of the simple sandwich immunoreaction approach, cardiac troponin-I antigen (cTnI), a kind of biomarker related with myocardial infarction, was chosen as a detection model using an IRMOF-3-enriched CdTe labeled antibody as the signal probe. This immunosensor demonstrated desirable assay performance for cTnI with a wide response range from 1.1 fg mL-1 to 11 ng mL-1 and a very low detection limit (0.46 fg mL-1). This suggested that the IRMOF-3-enriched CdTe nanocomposite strategy can integrate the coreactant accelerator and luminophore to significantly enhance the ECL intensity and stability, providing a direction for promising ECL tag preparation with broad applications.
Related Concept Videos
Quantum Numbers
The Quantum-Mechanical Model of an Atom
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
The Sense of Self: Reflected Self-Appraisal and Social Comparison

