Validity of activity trackers, smartphones, and phone applications to measure steps in various walking conditions
Related Experiment Video
Updated: Feb 14, 2026

Measuring the Switch Cost of Smartphone Use While Walking
Published on: April 30, 2020
C Höchsmann1, R Knaier1, J Eymann1
1Division of Sports and Exercise Medicine, Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland.
Abstract:
To examine the validity of popular smartphone accelerometer applications and a consumer activity wristband compared to a widely used research accelerometer while assessing the impact of the phone's position on the accuracy of step detection. Twenty volunteers from 2 different age groups (Group A: 18-25 years, n = 10; Group B 45-70 years, n = 10) were equipped with 3 iPhone SE smartphones (placed in pants pocket, shoulder bag, and backpack), 1 Samsung Galaxy S6 Edge (pants pocket), 1 Garmin Vivofit 2 wristband, and 2 ActiGraph wGTX+ devices (worn at wrist and hip) while walking on a treadmill (1.6, 3.2, 4.8, and 6.0 km/h) and completing a walking course. All smartphones included 6 accelerometer applications. Video observation was used as gold standard. Validity was evaluated by comparing each device with the gold standard using mean absolute percentage errors (MAPE). The MAPE of the iPhone SE (all positions) and the Garmin Vivofit was small (<3) for treadmill walking ≥3.2 km/h and for free walking. The Samsung Galaxy and hip-worn ActiGraph showed small MAPE only for treadmill walking at 4.8 and 6.0 km/h and for free walking. The wrist-worn ActiGraph showed high MAPE (17-47) for all walking conditions. The iPhone SE and the Garmin Vivofit 2 are accurate tools for step counting in different age groups and during various walking conditions, even during slow walking. The phone's position does not impact the accuracy of step detection, which substantially improves the versatility for physical activity assessment in clinical and research settings.
Related Concept Videos
Real-World Application of Classical Conditioning
Higher-order, or second-order, conditioning occurs when a neutral stimulus becomes associated with an already established conditioned stimulus through repeated pairings. For instance, if a dog has been...
Reliability and Validity
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...

