Related Experiment Video
Updated: Feb 14, 2026

Generating Lap Joints Via Friction Stir Spot Welding on DP780 Steel
Published on: August 13, 2019
Rehabilitations with immediate loading of one-piece implants stabilized with intraoral welding
M E Pasqualini1, D Lauritano2, F Rossi3
1MD DDS Private practice Milano, Italy.
Abstract:
The authors present an implant prosthesis procedure that uses screws on one-piece implants connected with a titanium pin at their abutment level and one supporter titanium bar in order to guarantee immediate stabilization. These can be implanted and fitted with customized temporary crowns in a single surgical procedure, restoring function and aesthetics and consenting recovery of the bone deficit with reduced healing times and limited patient discomfort. One-piece wide-diameter titanium screw implants with thread measurements of 2.1 and 2.6 mm (smaller diameter) up to diameter of 4.5 mm with one abutment of 2.0 and 2.5 mm respectively, were positioned and splinted by intraoral welding. One-piece titanium implants were used together with a pin (needle) titanium implant as supporting structure to achieve deep stabilization. The Scialom-like pin has a diameter of 1.2 mm and it is long enough to reach deep cortical bone that is bicorticalism. The One-piece implant is tightly connected to the needle implant by means of Mondani intra-oral welding technique. In severely atrophic anterior maxilla, the use of this method allows the immediate loading of a fixed resin prosthesis soon after surgery. These implants yielded satisfactory functional and aesthetic outcome in bone-deficient upper anterior sectors, without invasive regenerative procedures. The low invasiveness of this approach also consents rapid healing, reduced biological burden and greater patient benefit.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Stability of structures
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...

