Related Experiment Video
Updated: Feb 14, 2026

Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Radiomics Based on Adapted Diffusion Kurtosis Imaging Helps to Clarify Most Mammographic Findings Suspicious for
Sebastian Bickelhaupt1, Paul Ferdinand Jaeger1, Frederik Bernd Laun1
1From the Department of Radiology (S.B., L.W., D.P., D.B., A.R., S.D., H.P.S., F.S.), Division of Medical Image Computing (P.F.J., K.H.M.H.), and Department of Medical Physics in Radiology (F.B.L., T.A.K.), German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Institute of Radiology, University Hospital Erlangen, Erlangen, Germany (F.B.L.); Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg, Germany (W.L.); and Radiology Center Mannheim, Mannheim, Germany (H.D.).
Abstract:
Purpose To evaluate a radiomics model of Breast Imaging Reporting and Data System (BI-RADS) 4 and 5 breast lesions extracted from breast-tissue-optimized kurtosis magnetic resonance (MR) imaging for lesion characterization by using a sensitivity threshold similar to that of biopsy. Materials and Methods This institutional study included 222 women at two independent study sites (site 1: training set of 95 patients; mean age ± standard deviation, 58.6 years ± 6.6; 61 malignant and 34 benign lesions; site 2: independent test set of 127 patients; mean age, 58.2 years ± 6.8; 61 malignant and 66 benign lesions). All women presented with a finding suspicious for cancer at x-ray mammography (BI-RADS 4 or 5) and an indication for biopsy. Before biopsy, diffusion-weighted MR imaging (b values, 0-1500 sec/mm2) was performed by using 1.5-T imagers from different MR imaging vendors. Lesions were segmented and voxel-based kurtosis fitting adapted to account for fat signal contamination was performed. A radiomics feature model was developed by using a random forest regressor. The fixed model was tested on an independent test set. Conventional interpretations of MR imaging were also assessed for comparison. Results The radiomics feature model reduced false-positive results from 66 to 20 (specificity 70.0% [46 of 66]) at the predefined sensitivity of greater than 98.0% [60 of 61] in the independent test set, with BI-RADS 4a and 4b lesions benefiting from the analysis (specificity 74.0%, [37 of 50]; 60.0% [nine of 15]) and BI-RADS 5 lesions showing no added benefit. The model significantly improved specificity compared with the median apparent diffusion coefficient (P < .001) and apparent kurtosis coefficient (P = .02) alone. Conventional reading of dynamic contrast material-enhanced MR imaging provided sensitivity of 91.8% (56 of 61) and a specificity of 74.2% (49 of 66). Accounting for fat signal intensity during fitting significantly improved the area under the curve of the model (P = .001). Conclusion A radiomics model based on kurtosis diffusion-weighted imaging performed by using MR imaging machines from different vendors allowed for reliable differentiation between malignant and benign breast lesions in both a training and an independent test data set. © RSNA, 2018 Online supplemental material is available for this article.
More Related Videos
Related Concept Videos
Microsoft Excel: Finding Central Tendency, Skew, and Kurtosis
Mean: The arithmetic average of all data points. It is calculated by adding all the values together and dividing by the number of values. The mean is sensitive to extreme values (outliers).
Median: The middle value when the data points are arranged in ascending or descending...
Adaptive Mechanisms in Cancer Cells
Some of the advantages that cancer cells have on normal cells include - enhanced ability to divide without terminally differentiating, induce new blood vessel formation,...
Diffusion
Diffusion
Finding the Center of Gravity
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection