Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Investigating the Mechanism of Action of Acupotomy in Treating Knee Osteoarthritis
Published on: October 20, 2023
The determination of the validity of an application-based knee-training device
Hauke Horstmann1, Eva Krost2, Bastian Welke3
1Department of Orthopaedic Surgery, Hannover Medical School, Hannover, Germany.
Abstract:
The goals of knee rehabilitation are to improve range of motion and muscle status. The aim of the study was to investigate accuracy and reproducibility of a newly designed knee-training device (KT) under standardized laboratory conditions.Two application-based software programs, one to measure maximum force and the other intended to improve users' coordination were developed to be used on a tablet during exercises, wirelessly connected to KT placed under the popliteal fossa.KT was loaded for 20 intervals of 15 seconds (s) ranging between 0-350 Newton (N) each. The interval of times was chosen to be enough to take right measurement for accurate results. In addition, a 300-s continuous measurement was undertaken. The pressure readings were developed through a servo-hydraulic system and used as reference values. KT results were compared with the reference values to assess its accuracy. In addition, KT was tested on a force-measuring platform in a close to reality measurement.Based on Bland-Altman plots, the mean difference between KT and material testing machine was -0.63 N (0.4%), between KT and force-measuring platform was -0.11 N (0.7%), which proves the accuracy of its result.Laboratory experiments confirm that KT delivers precise and reproducible values, which provide base for clinical trials.
Related Concept Videos
Reliability and Validity
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Determining the pH of Salt Solutions