Related Experiment Video
Updated: Feb 14, 2026

3D Human Myocardial Tissue Generation Using Melt Electrospinning Writing of Polycaprolactone Scaffolds and hiPSC-Derived Cardiac Cells
Published on: March 28, 2025
Fabrication of transparent hemispherical 3D nanofibrous scaffolds with radially aligned patterns via a novel
Jeong In Kim1, Ju Yeon Kim2, Chan Hee Park3,4
1Department of Bionanosystem Engineering, Graduate School, Chonbuk National University, Jeonju, 561-756, Republic of Korea.
Abstract:
Tissue engineering has significantly contributed to the development of optimal treatments for individual injury sites based on their unique functional and histologic properties. Human organs and tissue have three-dimensional (3D) morphologies; for example, the morphology of the eye is a spherical shape. However, most conventional electrospinning equipment is only capable of fabricating a two-dimensional (2D) structured fibrous scaffold and no report is available on a 3D electrospinning method to fabricate a hemispherical scaffold to mimic the native properties of the cornea, including microscopic to macroscopic morphology and transparency. We proposed a novel electrospinning method using a single nonconductive hemispherical device and a metal pin. A designed peg-top shaped collector, a hemispherical nonconductive device with a metal pin in the center and copper wire forming a circle around at the edge was attached to a conventional conductive collector. A 3D hemispherical transparent scaffold with radially aligned nanofibers was successfully fabricated with the designed peg-top collector. In summary, our fabricated 3D electrospun scaffold is expected to be suitable for the treatment of injuries of ocular tissues owing to the hemispherical shape and radially aligned nanofibers which can guide the direction of the main collagen and cellular actin filament in the extracellular matrix.
More Related Videos
12:28Melt Electrospinning Writing of Three-dimensional Poly(ε-caprolactone) Scaffolds with Controllable Morphologies for Tissue Engineering Applications
Published on: December 23, 2017
10:08Author Spotlight: Advancing 3D Coculture Systems with PVA-PCL Nanofibrous Membranes
Published on: December 27, 2024
Related Concept Videos
Cerebral Hemispheres
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Fixed Action Patterns
Design Example: Alignment of a Road Line Using GIS