Related Experiment Video
Updated: Feb 14, 2026

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
Indoor radon concentration in Korea residential environments
Tae Hyun Park1, Dae Ryong Kang2, Si Hyun Park3
1Department of Chemical and Biological Engineering, SeoKyeong University, Seoul, 02713, South Korea. thp119@skuniv.ac.kr.
Abstract:
The purpose of this study is to provide basic data for the evaluation and management of health effects with respect to exposure to radon within residential environments in South Korea. It is part of a case-control study to develop a management plan based on indoor radon exposure levels and assess their impact on health. To investigate the long-term cumulative concentration levels of radon, 599 patients who have respiratory diseases were recruited in South Korea, and alpha track detectors were installed in their residences for a period of 3 months from mid-2015 to late 2016. A survey was then conducted to determine the factors affecting the radon concentration. The radon concentration levels were analyzed in conjunction with the survey results. The results show that the arithmetic mean of the radon concentrations in domestic residences was in the range of 70.8 ± 65.2 Bq/m3. An analysis of covariance (ANCOVA) was performed to identify the environmental factors affecting the radon concentration and contributing to variations in the residential radon concentration based on the height of the residence. The results show that the contribution of the local environmental factor to the variation in radon concentration (p < 0.05) was greater than that of other environmental factors. Although no statistically significant difference was found with regard to the construction year of the building before the control (p > 0.05), the same was found with regard to the construction year after the control (p < 0.05).
More Related Videos
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
15:30A Telemetric, Gravimetric Platform for Real-Time Physiological Phenotyping of Plant–Environment Interactions
Published on: August 5, 2020
Related Concept Videos
Design Example: Designing a Residential Plumbing System
Concentration Cells
Consider the following voltaic cell:
Solution Concentration and Dilution
Stress Concentrations
The stress...
Stress Concentrations
Concentration and Rate Law
For example, in a generic reaction aA + bB ⟶ products, where a and b are stoichiometric coefficients, the rate law can be written as: