Prediction of GTV median dose differences eases Monte Carlo re-prescription in lung SBRT
D Dechambre1, L Z Janvary2, N Jansen1
1Liege University Hospital, Department of Radiation Oncology, Liège, Belgium.
Background And Purpose:
The use of Monte Carlo (MC) dose calculation algorithm for lung patients treated with stereotactic body radiotherapy (SBRT) can be challenging. Prescription in low density media and time-consuming optimization conducted CyberKnife centers to propose an equivalent path length (EPL)-to-MC re-prescription method based on GTV median dose. Unknown at the time of planning, GTV D50% practical application remains difficult. The current study aims at creating a re-prescription predictive model in order to limit conflicting dose value during EPL optimization.
Material And Methods:
129 patients planned with EPL algorithm were recalculated with MC. Relative GTV_D50% discrepancies were assessed and influencing parameters identified using wrapper feature selection. Based on best descriptive parameters, predictive nomogram was built from multivariate linear regression. EPL-to-MC OARs near max-dose discrepancies were reported.
Results:
The differences in GTV_D50% (median 10%, SD: 9%) between MC and EPL were significantly (p < .001) impacted by the lesion's surface-to-volume ratio and the average relative electronic density of the GTV and the GTV's 15 mm shell. Built upon those parameters, a nomogram (R2 = 0.79, SE = 4%) predicting the GTV_D50% discrepancies was created. Furthermore EPL-to-MC OAR dose tolerance limit showed a strong linear correlation with coefficient range [0.84-0.99].
Conclusion:
Good prediction on the required re-prescription can be achieved prior planning using our nomogram. Based on strong linear correlation between EPL and MC for OARs near max-dose, further restriction on dose constraints during the EPL optimization can be warranted. This a priori knowledge eases the re-prescription process in limiting conflicting dose value.
More Related Videos
13:18Network Pharmacology Prediction and Experimental Validation of Trichosanthes-Fritillaria thunbergii Action Mechanism Against Lung Adenocarcinoma
Published on: March 3, 2023
05:56Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Related Concept Videos
Median
Sign Test for Median of Single Population
Prescription, Nonprescription and Orphan Drugs
The misuse and addiction to prescription drugs is a growing problem that can affect people of all age groups, specifically teenagers. This can happen when prescription medications are used in ways not intended by the prescriber, such as taking someone else's prescription or using medication for...
Predicting Molecular Geometry
Lung Capacity
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...