Stability of Locking Plate and Compression Screws for Lapidus Arthrodesis: A Biomechanical Comparison of Plate
David Drummond1, Travis Motley2, Victor Kosmopoulos2
1Clinical Instructor, Department of Surgery, Louisiana State University Health Science Center, Shreveport, LA.
Abstract:
Lapidus (first tarsometatarsal joint) arthrodesis is an established and widely used procedure for the management of moderate to severe hallux valgus, especially in cases involving hypermobility of the first tarsometatarsal joint. Multiple fixation methods are available, and several previous investigations have studied the relative strengths of these methods, including dorsomedial and plantar plating comparisons. However, these studies compared plates of varying designs and mechanical properties and used varying modes of compression and interfragmentary screw techniques. The present study mechanically investigated the resulting motion, stiffness, and strength of identical locking plate constructs fixed at various anatomic positions around the first tarsometatarsal joint. In a bench-top study, fourth-generation composite bones were divided into 3 fixation groups, each having identical interfragmentary screw applications, and randomized to 1 of 3 plate positions: dorsal, medial, or plantar. The plates applied in each case were identical locking plates, precontoured to fit the anatomy. Each construct was experimentally tested using a cantilever bending approach. The outcomes obtained were stiffness, yield force, displacement at yield, ultimate force, and displacement at ultimate force. The plantar plate position showed superior initial stiffness and force to ultimate failure. The plantar and medial plate positions exhibited superior force to yield. The medial plate position was superior regarding displacement tolerated before the yield point and catastrophic failure. The dorsal plate position was not superior for any outcome measured. Plantar and medial plating each offered biomechanical benefits. Clinical studies using similarly matched constructs are required to show whether these findings translate into improved clinical outcomes.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width
Steady, Laminar Flow Between Parallel Plates
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
