An Evaluation of Output Signal to Noise Ratio as a Predictor of Cochlear Implant Speech Intelligibility
Greg D Watkins1, Brett A Swanson2, Gregg J Suaning1
1Faculty of Engineering and Information Technologies, School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, Sydney, Australia.
Objectives:
Cochlear implant (CI) sound processing strategies are usually evaluated in clinical studies involving experienced implant recipients. Metrics which estimate the capacity to perceive speech for a given set of audio and processing conditions provide an alternative means to assess the effectiveness of processing strategies. The aim of this research was to assess the ability of the output signal to noise ratio (OSNR) to accurately predict speech perception. It was hypothesized that compared with the other metrics evaluated in this study (1) OSNR would have equivalent or better accuracy and (2) OSNR would be the most accurate in the presence of variable levels of speech presentation.
Design:
For the first time, the accuracy of OSNR as a metric which predicts speech intelligibility was compared, in a retrospective study, with that of the input signal to noise ratio (ISNR) and the short-term objective intelligibility (STOI) metric. Because STOI measured audio quality at the input to a CI sound processor, a vocoder was applied to the sound processor output and STOI was also calculated for the reconstructed audio signal (vocoder short-term objective intelligibility [VSTOI] metric). The figures of merit calculated for each metric were Pearson correlation of the metric and a psychometric function fitted to sentence scores at each predictor value (Pearson sigmoidal correlation [PSIG]), epsilon insensitive root mean square error (RMSE*) of the psychometric function and the sentence scores, and the statistical deviance of the fitted curve to the sentence scores (D). Sentence scores were taken from three existing data sets of Australian Sentence Tests in Noise results. The AuSTIN tests were conducted with experienced users of the Nucleus CI system. The score for each sentence was the proportion of morphemes the participant correctly repeated. In data set 1, all sentences were presented at 65 dB sound pressure level (SPL) in the presence of four-talker Babble noise. Each block of sentences used an adaptive procedure, with the speech presented at a fixed level and the ISNR varied. In data set 2, sentences were presented at 65 dB SPL in the presence of stationary speech weighted noise, street-side city noise, and cocktail party noise. An adaptive ISNR procedure was used. In data set 3, sentences were presented at levels ranging from 55 to 89 dB SPL with two automatic gain control configurations and two fixed ISNRs.
Results:
For data set 1, the ISNR and OSNR were equally most accurate. STOI was significantly different for deviance (p = 0.045) and RMSE* (p < 0.001). VSTOI was significantly different for RMSE* (p < 0.001). For data set 2, ISNR and OSNR had an equivalent accuracy which was significantly better than that of STOI for PSIG (p = 0.029) and VSTOI for deviance (p = 0.001), RMSE*, and PSIG (both p < 0.001). For data set 3, OSNR was the most accurate metric and was significantly more accurate than VSTOI for deviance, RMSE*, and PSIG (all p < 0.001). ISNR and STOI were unable to predict the sentence scores for this data set.
Conclusions:
The study results supported the hypotheses. OSNR was found to have an accuracy equivalent to or better than ISNR, STOI, and VSTOI for tests conducted at a fixed presentation level and variable ISNR. OSNR was a more accurate metric than VSTOI for tests with fixed ISNRs and variable presentation levels. Overall, OSNR was the most accurate metric across the three data sets. OSNR holds promise as a prediction metric which could potentially improve the effectiveness of sound processor research and CI fitting.
Related Concept Videos
Intelligence
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Measures of Intelligence
Validity refers to how well a test measures what it claims to measure. An intelligence test should accurately assess intelligence rather than another characteristic, like anxiety. Criterion validity is one way to evaluate this;...
Poisson's Ratio
Odds Ratio