Related Experiment Video
Updated: Feb 14, 2026

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac
Toru Higaki1, Takeshi Nakaura2, Masafumi Kidoh2
1Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Kasumi, Minami-ku, Hiroshima, Japan.
Abstract:
Arterial peak enhancement on contrast-enhanced CT (CECT) images is thought to be higher in patients with low cardiac function. Using computer simulations, we tested the hypothesis that the relationship between the cardiac index and the aortic peak CT number (PCTN) is affected by the contrast material (CM) injection duration. We created computer simulation software for the contrast enhancement of various organs and vessels based on the Bae pharmacokinetics model and implemented models for CM transmission within organs and CM diffusion in blood plasma based on the osmotic pressure. Aortic contrast enhancement at coronary- and abdominal CT angiographs (CTA) was simulated for a representative 60-year-old Japanese male 166 cm in height and 65.0 kg in weight. The injection protocol for coronary CTA was: CM dose 45.5 ml, iodine dose, 245 mg/kg body weight (BW); injection duration 8-20 sec in 2-sec increments. For abdominal CTA it was CM dose 74.3 ml; iodine dose 400 mg/kg BW; injection duration 10-40 sec in 5-sec increments. In both protocols the iodine concentration was 350 mgI/ml, osmotic pressure was 590 mOsm/kgH2O, and the cardiac index ranged from 0.1-6.0 l/min/m2. Under all protocols, the aortic PCTN increased as the injection duration decreased and as the cardiac index rose to the cardiac index value. It then decreased as it exceeded the cardiac index value. At coronary CTA, at an injection duration of 8 or 10 sec, the PCTN exceeded 350 Hounsfield units (HU) at a cardiac index from 0.9-5.6 l/min/m2. At an HU value greater than 350, the range of the cardiac index narrowed when the injection duration was 12 sec or longer. On abdominal CTA scans performed with an injection duration of 10-, 15-, or 20 sec, the PCTN exceeded 350 HU at a cardiac index ranging from 0.4-5.3 l/min/m2. When the injection duration ranged from 25-40 sec, there was narrowing of the range of the cardiac index at which the PCTN exceeded 350 HU. For coronary and abdominal CTA, contrast enhancement protocols with shorter injection durations yield a diagnostically adequate aortic PCTN at a wide range of cardiac indices.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Indicators
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Genetic Material
Members Made of Elastoplastic Material
As the bending moment...
Mechanical Ventilation I: Indication and Settings
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...