Related Experiment Video
Updated: Feb 14, 2026

Pressure Controlled Ventilation to Induce Acute Lung Injury in Mice
Published on: May 5, 2011
Effects of Pressure-Controlleda Volume-Controlled Ventilation on Hemodynamic and Respiratory Parameters in Patients
Mirko Mihalj1, Dajana Vladić1, Zoran Karlović1
1Mostar University Hospital, Department of Anesthesia, Resuscitation and Intensive Care, Mostar, Bosnia and Herzegovina.
Abstract:
Many papers have been published investigating the effects of intraoperative mechanical ventilation on the incidence of intra- and postoperative respiratory complications. The potential advantages of protective pressure over volume-controlled ventilation mode during laparoscopic surgery have yet to be proven. This study included 60 patients aged between 18 and 70 with ASA score 1-3, body mass index (BMI) ≤35 kg/m2, and without prior history of chronic respiratory diseases, who were scheduled for laparoscopic cholecystectomy under general anesthesia. Patients were assigned randomly to protective pressure or volume-controlled mechanical ventilation mode. The initial results showed no significant differences in respiratory and hemodynamic parameters between the groups. Comparison of patients with BMI ≥25 showed significantly lower peak inspiratory pressure (Ppeak) at 15 (18.52 vs. 21.83 cm H2O, p=0.022), 30 (18.73 vs. 21.83 cm H2O, p=0.009) and 45 (18.94 vs. 22.667 cm H2O, p=0.010) minutes after tracheal intubation in the pressure-controlled ventilation (PCV) group. Other measured parameters were of similar characteristics. It is concluded that PCV and volume-controlled ventilation were equally effective in maintaining adequate ventilation, oxygenation and hemodynamic stability in the groups of patients observed. However, comparison of obese patients revealed some advantages of PCV which, given the present pace of change, should be additionally investigated.
Related Concept Videos
Control Volume and System Representations
The control volume approach considers a stationary region in space through which fluid flows. This region is bounded by a control surface. For instance, in the case of water...
Linear Momentum in Control Volume
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...