Related Experiment Video
Updated: Feb 14, 2026

Developing a Virtual Reality Video Game to Simulate Rip Currents
Published on: July 16, 2020
Development and Initial Evaluation of a Novel, Ultraportable, Virtual Reality Bronchoscopy Simulator: The Computer
Gabriele Casso1, Patrick Schoettker2, Georges L Savoldelli3
1From the Department of Cardiac Anesthesia and Intensive Care, Cardiocentro Ticino, Lugano, Switzerland.
Background:
Virtual reality (VR) simulation is an effective and safe method of teaching bronchoscopic skills. Few VR bronchoscopy simulators exist; all are expensive. The present study aimed to describe the design, development, and evaluation of a new, affordable, VR bronchoscopy simulator.
Methods:
Anesthesiologists and engineers collaborated to design and develop the Computer Airway Simulation System (CASS), an iPad-based, high-fidelity, VR bronchoscopy simulator. We describe hardware and software development, as well as the technical and teaching features of the CASS. Twenty-two senior anesthesiologists evaluated various aspects of the simulator (using a 5-point Likert scale) to assess its face validity.
Results:
Anesthesiologists performed a simulated bronchoscopy (mouth to carina) with a median (range) procedural time of 66 seconds (30-96). The simulator's ease of use was rated 4.3 ± 0.8 and the bronchoscope proxy's handling 4.0 ± 0.7. Criticisms included that excessive system reactivity created handling difficulties. Anatomical accuracy, 3-dimensional bronchial segmentation, and mucosal texture were judged to be very realistic. The simulator's usefulness for teaching and its educational value were highly rated (4.9 ± 0.3 and 4.8 ± 0.4, respectively).
Conclusions:
We describe the design, development, and initial evaluation of the CASS-a new, ultraportable, affordable, VR bronchoscopy simulator. The simulator's face validity was supported by excellent assessments from senior anesthesiologists with regard to anatomical realism, quality of graphics, and handling performance, even though some future refinements are required. All the practitioners agreed on the significant educational potential of the CASS.
Related Concept Videos
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Transcription Initiation
The promoters and enhancers and their accessory proteins allow tight regulation of...
Suctioning the Nasopharyngeal Airway
Equipment Required