THE RELIABILITY OF A NOVEL HEEL-RISE TEST VERSUS GONIOMETRY TO ASSESS PLANTARFLEXION RANGE OF MOTION
Brandon M Ness1, Ramu G Sudhagoni1, Hanz Tao1
1University of South Dakota, Vermillion, SD, USA.
Background:
Ankle plantarflexion (PF) active range of motion (ROM) is traditionally assessed in a non-weight-bearing (NWB) position with a universal goniometer. However, a convenient, reliable, low-cost means of assessing functional PF active ROM in a weight-bearing (WB) position has yet to be established.
Purpose:
To compare the intra- and interrater reliability of PF active ROM measurements obtained from a goniometric NWB assessment, and a functional heel-rise test (FHRT) performed in WB.
Study Design:
Reliability study.
Methods:
Two physical therapy student examiners, blinded to each other's measurements, assessed PF active ROM through a NWB goniometric technique and a FHRT on all subjects within the same test session. Intra- and interrater reliability values were calculated using an intraclass correlation coefficient (ICC2,1, ICC2,k) and 95% confidence intervals. Standard error of measurement (SEM) and minimal detectable change (MDC) were recorded for each method.
Results:
43 healthy participants (mean ± SD, age: 22.7 ± 1.7 years, height: 1.7 ± 0.1 m, mass: 77.8 ± 17.2 kg) completed testing procedures. The within-session intrarater reliability (ICC2,1) estimates were observed for goniometry (right: 0.96, left: 0.95 - 0.97) and FHRT (right: 0.99, left: 0.99), as well as the interrater reliability (ICC2,k) of goniometry (right: 0.79, left: 0.79) and FHRT (right: 0.79, left: 0.87). Goniometry SEM (3.3 - 3.6 °) and MDC (9.2 - 9.8 °) were observed, in addition to FHRT SEM (0.6 cm) and MDC (1.6 - 1.7 cm). A weak correlation was found between FHRT and goniometric measurements (r = -0.03 - 0.13).
Conclusions:
The FHRT was found to have good to excellent intra- and interrater reliability, similar to goniometric measurement. The lack of agreement between these measurements requires further exploration of a WB assessment of ankle PF active ROM.
Level Of Evidence:
2b.
More Related Videos
Related Concept Videos
Reliability and Validity
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Rise of Liquid in a Capillary Tube
Variation: Normal Distribution, Range, and Standard Deviation
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...
Distribution Reliability and Automation