Related Experiment Video
Updated: Feb 13, 2026

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
A 10-Year Prospective Study of Implant-Based Breast Augmentation and Reconstruction
Robert El-Haddad1, Béatrice Lafarge-Claoue2, Charles Garabedian3
1Centre Chirurgical des Princes, Boulogne Billancourt, France.
Abstract:
Objective: Observational studies are essential for ensuring patient safety, decreasing complications, and developing better surgical techniques and implants. The primary objective of this study is to demonstrate the safety and efficacy of Sebbin breast implants in both augmentation and reconstruction cohorts. Methods: This prospective, multicenter, observational 10-year study conducted in France included 205 patients (385 implants) who underwent breast augmentation (n = 166) or reconstruction (n = 39) with Sebbin round silicone gel implants. Data on patient demographics, surgical details, and complications were collected. Results: Median patient age was 39 years; 20.5% of patients were smokers. The augmentation cohort included 166 patients (81.0%); the reconstruction cohort, 39 patients (19.0%). Median implant volume was 280 ml; 91.2% of implants were textured, and 8.8% were smooth. Average patient follow-up was 63 months. The most frequent surgical approach in the Augmentation Cohort was periareolar (72.4%), with 45.5% submuscular and 51.5% subglandular placements. All patients received antibiotic prophylaxis, and postoperative antibiotic therapy was given to 39.5% of patients (average 4.8 days). Drainage was performed in 59.5% of patients (average 2.9 days). Of the reconstruction cohort, 64.1% had preoperative radiotherapy. Nine patients had Baker III/IV capsular contracture (3 bilateral; 4 had a history of radiotherapy) and 7 patients had implant rupture; 41 patients underwent explantation. No cases of double capsule, late seroma, or anaplastic large cell lymphoma occurred. Conclusions: This study found an excellent safety profile and very low capsular contracture rate with breast augmentation and reconstruction using Sebbin round silicone gel implants.
More Related Videos
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
Related Concept Videos
Reconstruction of Signal using Interpolation
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Case Studies
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Weak Base Solutions
Base Excision Repair
The first step of...