Radiation exposure during TACE procedures using additional cone-beam CT (CBCT) for guidance: safety and precautions
M Jonczyk1,2, F Collettini1,2, D Geisel1
11 Department of Radiology, Charité University Medicine Berlin, Berlin, Germany.
Abstract:
Background During transarterial chemoembolization (TACE), cone-beam computed tomography (CBCT) can be used for tumor and feeding vessel detection as well as postembolization CT imaging. However, there will be additional radiation exposure from CBCT. Purpose To evaluate the additional dose raised through CBCT-assisted guidance in comparison to TACE procedures guided with pulsed digital subtraction angiography (DSA) alone. Material and Methods In 70 of 140 consecutive patients undergoing TACE for liver cancer, CBCT was used to facilitate the TACE. Cumulative dose area product (DAP), cumulative kerma(air), DAP values of DSA, total and cine specific fluoroscopy times (FT) of 1375 DSA runs, and DAP of 91 CBCTs were recorded and analyzed using Spearman's correlation, Mann-Whitney U-test, and Kruskal-Wallis test. P values < 0.05 were considered significant. Results Additional CBCT increased DAP by 2% ( P = 0.737), kerma(air) by 24.6% ( P = 0.206), and FT by 0.02% ( P = 0.453). Subgroup analysis revealed that postembolization CBCT for detection of ethiodized oil deposits added more DAP to the procedure. Performing CBCT-assisted TACE, DSA until first CBCT contributed about 38% to the total DAP. Guidance CBCT acquisitions conduced to 6% of the procedure's DAP. Additional DSA for guidance after CBCT acquisition required approximately 46% of the mean DAP. The last DSA run for documentation purposes contributed about 10% of the DAP. Conclusion CBCT adds radiation exposure in TACE. However, the capability of CBCT to detect vessels and overlay in real-time during fluoroscopy facilitates TACE with resultant reduction of DAPs up to 46%.
More Related Videos
11:13Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Biological Effects of Radiation
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Survey Safety
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Radiation: Applications
The average...