Related Experiment Video
Updated: Feb 13, 2026

Proteomic Profile of EPS-Urine through FASP Digestion and Data-Independent Analysis
Published on: May 8, 2021
Simultaneous accurate quantification of HO-1, CD39, and CD73 in human calcified aortic valves using multiple enzyme
Mariola Olkowicz1, Patrycja Jablonska2, Jan Rogowski3
1Department of Biochemistry, Medical University of Gdansk, 1 Debinki St., 80-211 Gdansk, Poland; Department of Biotechnology and Food Microbiology, Poznan University of Life Sciences, 48 Wojska Polskiego St., 60-627 Poznan, Poland.
Abstract:
Several proteins such as membrane-associated ectonucleotidases: ecto-5'-nucleotidase (E5NT/CD73) and ectonucleoside triphosphate diphosphohydrolase 1 (ENTPD1/CD39), and intracellular heme oxygenase-1 (HO-1) may contribute to protection from inflammation-related diseases such as calcific aortic valve stenosis (CAS). Accurate quantification of these proteins could contribute to better understanding of the disease mechanisms and identification of biomarkers. This report presents development and validation of quantification method for E5NT/CD73, ENTPD1/CD39 and HO-1. The multiplexed targeted proteomic assay involved antibody-free, multiple-enzyme digestion, filter-assisted sample preparation (MED-FASP) strategy and a nanoflow liquid chromatography/mass spectrometry under multiple reaction monitoring mode (LC-MRM/MS). The method developed presented high sensitivity (LLOQ of 5 pg/mL for each of the analytes) and accuracy that ranged from 92.0% to 107.0%, and was successfully applied for the absolute quantification of HO-1, CD39 and CD73 proteins in homogenates of human calcified and non-calcified valves. The absolute CD39 and CD73 concentrations were lower in calcified aortic valves (as compared to non-stenotic ones) and were found to be: 1.16 ± 0.39 vs. 3.15 ± 0.37 pmol/mg protein and 1.94 ± 0.21 vs. 2.39 ± 0.39 pmol/mg protein, respectively, while the quantity of HO-1 was elevated in calcified valves (10.72 ± 1.18 vs. 4.28 ± 0.42 amol/mg protein). These results were consistent but more reproducible as compared to immunoassays. In conclusion, multiplexed quantification of HO-1, CD39 and CD73 proteins by LC-MRM/MS works well in challenging human tissues such as aortic valves. This analysis confirmed the relevance of these proteins in pathogenesis of CAS and could be extended to other biomedical investigations.
Related Concept Videos
What is Monogastric Digestion?
Carbohydrate Digestion
Protein Digestion
Lipid Digestion
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Enzymes
Enzyme deficiencies can often translate into life-threatening diseases. For example, a genetic abnormality resulting in the deficiency of the enzyme G6PD...