Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Biological Effects of Radiation02:59

Biological Effects of Radiation

18.1K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
18.1K
Trial and Error and Algorithm01:12

Trial and Error and Algorithm

430
A problem-solving strategy is a plan of action used to find a solution. Different strategies have distinct action plans. Trial and error involves trying different solutions until one works. For instance, to fix a broken printer, you might check ink levels, ensure the paper tray isn't jammed, and verify the printer's connection to your laptop. This method can be time-consuming but is commonly used. Thomas Edison, for example, used trial and error to find a suitable filament for the light...
430
Radiation: Applications01:17

Radiation: Applications

1.8K
The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
1.8K
Absorption of Radiation01:05

Absorption of Radiation

1.3K
The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
1.3K
Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

329
Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
329
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

252
A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
252

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exploring Diagnostic Challenges: A Case Report Commentary on "Solving a Diagnostic Dilemma in a Patient With Periodic Fever-When the Pieces of the Puzzle Finally Fit".

Clinical case reports·2026
Same author

Proj2Proj: self-supervised low-dose CT reconstruction.

PeerJ. Computer science·2024
Same author

Maximum-A-Posteriori Estimation of Retinal Oxygen Tension Based on Photon Counting Statistics.

IEEE transactions on bio-medical engineering·2024
Same author

Tracing 2D Growth of Pancreatic Tumoroids Using the Combination of Image Processing Techniques and Mini-Opto Tomography Imaging System.

Technology in cancer research & treatment·2023
Same author

A Realistic Breast Phantom Proposal for 3D Image Reconstruction in Digital Breast Tomosynthesis.

Technology in cancer research & treatment·2022
Same author

A Novel Parametric Model for the Prediction and Analysis of the COVID-19 Casualties.

IEEE access : practical innovations, open solutions·2022

Related Experiment Video

Updated: Feb 13, 2026

Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction
12:38

Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction

Published on: August 9, 2011

17.9K

An iterative reconstruction algorithm for digital breast tomosynthesis imaging using real data at three radiation

Adem Polat1,2, Isa Yildirim2,3

  • 1Department of Medicine, Division of Engineering in Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, USA.

Journal of X-Ray Science and Technology
|March 6, 2018
PubMed
Summary

Researchers developed a new image reconstruction method to improve breast cancer screening quality while lowering radiation exposure. By combining advanced mathematical algorithms, this approach creates clearer 3D images from fewer X-ray projections than standard techniques. Testing showed this method consistently outperformed conventional imaging in clarity and detail across various radiation levels.

Keywords:
3D total variationDigital breast tomosynthesisalgebraic reconstruction techniqueiterative reconstructionmajorization-minimizationreal DBT imageX-ray imagingimage denoisingradiation dose reductionmedical physics

Frequently Asked Questions

More Related Videos

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.9K
Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

3.2K

Related Experiment Videos

Last Updated: Feb 13, 2026

Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction
12:38

Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction

Published on: August 9, 2011

17.9K
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.9K
Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

3.2K

Area of Science:

  • Medical imaging physics and Digital Breast Tomosynthesis optimization
  • Computational diagnostic radiology and signal processing

Background:

Current breast screening technology faces significant challenges regarding patient radiation exposure during three-dimensional imaging procedures. Standard reconstruction techniques often struggle to maintain high image clarity when radiation levels are minimized. No prior work had resolved how to effectively integrate advanced denoising algorithms into existing tomosynthesis workflows. That uncertainty drove the development of novel iterative approaches to enhance diagnostic precision. Prior research has shown that algebraic methods offer a viable alternative to traditional filtered back projection approaches. This gap motivated the exploration of sophisticated mathematical frameworks to refine image quality. It was already known that reducing X-ray dosage remains a primary objective for improving clinical safety. That limitation necessitated the investigation of new computational strategies for processing breast phantom data.

Purpose Of The Study:

This study aims to investigate a new iterative reconstruction method to reduce radiation exposure in breast imaging. The researchers sought to address the persistent challenge of maintaining high image quality at lower dose levels. By integrating algebraic techniques with advanced denoising, the team explored a potential solution for safer screening. The motivation stems from the need to minimize patient exposure while ensuring accurate detection of suspicious lesions. This work focuses on comparing the performance of the proposed algorithm against standard industry practices. The authors intended to provide quantitative evidence that iterative processing can surpass conventional filtered back projection. The investigation specifically targets the limitations of current three-dimensional breast imaging systems. This research seeks to validate a computational framework that optimizes the balance between radiation safety and diagnostic clarity.

Main Methods:

The research team implemented a novel computational pipeline to process breast phantom projections. Review approach involved applying an algebraic reconstruction technique integrated with three-dimensional total variation denoising. The investigators utilized a majorization-minimization algorithm to further refine the reconstructed signals. Data acquisition occurred using a standard commercial mammography system to ensure clinical relevance. The team tested three distinct radiation dose levels to evaluate performance under varying exposure conditions. Quantitative assessments included calculating contrast-to-noise ratios and full width at half maximum values for specific regions. Qualitative visual inspections complemented these numerical analyses to verify image fidelity. Comparison against the conventional filtered back projection method provided a baseline for measuring performance improvements.

Main Results:

The new method consistently outperformed the standard filtered back projection technique across all evaluated metrics. Key findings from the literature indicate that the proposed algorithm achieved significantly higher contrast-to-noise ratios in both tested regions. At 100 mAs, the new approach reached a ratio of 48.163 in the first region, compared to 0.955 for the conventional method. Visual assessments confirmed superior clarity and detail in the reconstructed images. Spatial resolution, measured by full width at half maximum, improved with the new method at all three dose levels. For instance, at 100 mAs, the new method achieved a value of 1.661, while the standard technique recorded 2.032. These results demonstrate that the iterative framework effectively preserves image quality while minimizing radiation. The data suggest that this approach successfully mitigates noise artifacts that typically degrade low-dose imaging.

Conclusions:

The proposed reconstruction framework demonstrates potential for lowering radiation exposure in clinical breast imaging. Authors suggest that this mathematical approach provides superior visual clarity compared to standard industry techniques. Quantitative metrics confirm that the new method enhances contrast and spatial resolution across all tested dose levels. Synthesis and implications indicate that these improvements could facilitate safer screening protocols for patients. Researchers emphasize that the integration of denoising algorithms effectively addresses common noise artifacts found in low-dose scans. The findings support the adoption of iterative techniques to optimize diagnostic performance in tomosynthesis systems. This study confirms that refined computational processing maintains high image standards even when input data is restricted. Future clinical implementation may benefit from the increased sensitivity and detail provided by this specific iterative model.

The researchers propose an iterative framework combining algebraic reconstruction, three-dimensional total variation, and majorization-minimization. This approach processes X-ray projections to generate clearer images than the standard filtered back projection method, specifically improving contrast-to-noise ratios and spatial resolution metrics.

The study utilizes a CD Pasmam 1054 breast phantom to simulate clinical conditions. This physical model allows for the controlled acquisition of projection data using a Siemens MAMMOMAT system across three distinct radiation dose levels.

A Siemens MAMMOMAT system is necessary to acquire the raw projection data. This hardware provides the standardized input required to compare the new iterative algorithm against the conventional filtered back projection technique under identical experimental conditions.

The study uses real projection data acquired from a physical phantom. This dataset serves as the foundation for testing the algorithm's ability to maintain high image quality while reducing radiation exposure compared to traditional methods.

The researchers measure contrast-to-noise ratios and full width at half maximum values. For example, at 100 mAs, the new method achieved a contrast-to-noise ratio of 48.163 in region of interest one, significantly outperforming the 0.955 value recorded by the filtered back projection method.

The authors propose that their method could help decrease radiation dose levels. They claim this reduction addresses a primary limitation of current tomosynthesis imaging, potentially improving safety without compromising the diagnostic detail needed for detecting suspicious lesions.