Meta-analysis of Renal Function Following Infrarenal EVAR using Suprarenal or Infrarenal Fixation Devices
Philip W Stather1, James Ferguson1, Ayoola Awopetu1
1Department of Vascular Surgery, Cambridge University Hospital, Hills Road, Cambridge, UK.
Objective/Background:
The effect of suprarenal (SR) as opposed to infrarenal (IR) fixation on renal outcomes post-endovascular aneurysm repair (EVAR) remains controversial. This meta-analysis aims to update current understanding of this issue.
Methods:
A prior meta-analysis was updated through a Preferred Reporting Items for Systematic reviews and Meta-Analyses search for additional studies published in the last 3 years reporting on renal dysfunction or related outcomes post-EVAR. Random effects meta-analysis was undertaken using SPSS.
Results:
A total of 25 non-randomised studies comparing SR with IR fixation were included, totalling 54,832 patients. In total, 16,634 underwent SR and 38,198 IR. Baseline characteristics, including age, baseline estimated glomerular filtration rate, diabetes, cardiac disease, and smoking, were similar between the groups. There was a small but significant difference in outcomes for renal dysfunction at the study end point (SR 5.98% vs. IR 4.83%; odds ratio [OR] 1.29, 95% confidence interval [CI] 1.18-1.40 [p < .001]); however, at 30 days and 12 months there was no significant difference, and this did not hold up to sensitivity analysis. Incidence of renal infarcts (SR 6.6% vs. IR 2.3%; OR 2.78, 95% CI 1.46-5.29 [p = .002]), renal stenosis (SR 2.4% vs. IR 0.8%; OR 2.89, 95% CI 1.00-8.38 [p = .05]), and renal artery occlusion (SR 2.4% vs. IR 1.2%; OR 2.21, 95% CI 1.15-4.25 [p = 0.02]) favoured IR fixation; however, there was no difference in haemodialysis rates.
Conclusion:
This meta-analysis has identified small but significantly worse renal outcomes in patients having SR fixation devices compared with IR; however, there was no difference in dialysis rates and a small effect on renal dysfunction, which did not stand up to rigorous sensitivity analysis. This should be taken into consideration during graft selection, and further studies must assess renal outcomes in the longer term, and in those with pre-existing renal dysfunction.
Related Concept Videos
Serum Studies: Renal Function Tests
Directing Effect of Substituents: meta-Directing Groups
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Carbon-dioxide Fixation
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...