Related Experiment Video
Updated: Feb 13, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well
Jordan Stubleski1, Petr Kukucka2, Samira Salihovic3
1MTM, School of Science and Technology, Örebro University, 701 82 Örebro, Sweden.
Abstract:
The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 μL of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs.
More Related Videos
Related Concept Videos
Volumes of Solids of Revolution
Calculation of Volume of Solids by Integration
Structures of Solids
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Phase Diagrams
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....

